Question: Does the laser/sindle head combo include the inverter?

Current Solution

Yes, if you purchase the option that includes the spindle, then the inverter (VFD - variable frequency drive) is included.

Respond:

Other Possible Solutions to this Question

  • What all is included in the GreenLean kit (sold with RedSprout and spindle/inverter)?

    The greenLean with the redSprout and the spindle option has everything you need excluding the spoilboard and the end mill.

    Click the link to respond:
    What all is included in the GreenLean kit (sold with RedSprout and spindle/inverter)?

  • What does an electronics combo include?

    There are a few electronic combos that include various motors and drivers, but common to all of these are the power supply (36v) and breakout board. The most common combo is the standard 3-axis combo which includes three 425 oz-in motors and three 3.0 amp drivers. The heavy gantry combo includes one 651 oz-in motor and 6.0 amp driver and two 425 oz-in motors and two 3.0 amp drivers. The combo for the greenBull CNC Machine kit is three 651 oz-in motors and three 6.0 amp drivers.

    Click the link to respond:
    What does an electronics combo include?

  • WHAT DOES THE GREENBULL KIT INCLUDE AND DO I NEED TO INCLUDE?

    The greenBull 4X comes with all of the components and electronics to assemble the gantry of the machine. You will need to build the table. We provide the rails and roller chain for the X-axis (along the length of the table for full 8 feet of travel). You will need to provide some wire to connect the electronics and a computer to run the machine. You will also need to purchase the software that you will need to run the machine that matches how you will apply the machine. We suggest the mach3 control program. The CAM program is up to you as there are many options out there.

    Click the link to respond:
    WHAT DOES THE GREENBULL KIT INCLUDE AND DO I NEED TO INCLUDE?

  • from the pictures of your combo#1 with plans and DVD are any MDF parts included?

    Wood structural parts are not included with combo #1 kit. If you would like a kit that contains all of the structural parts, hardware and electronics, consider the 2'x4' kit at this link:
    https://www.buildyourcnc.com/Item/cnc-machine-blacktoe-v4-2x4

    Of if a smaller routing are is needed, consider this 1'x3' kit:
    https://www.buildyourcnc.com/Item/cnc-machine-bluechick-v4

    Click the link to respond:
    from the pictures of your combo#1 with plans and DVD are any MDF parts included?

  • What does the greenBull kit include and what do I need to include?

    The greenBull 4X comes with all of the components and electronics to assemble the gantry of the machine. You will need to build the table. We provide the rails and roller chain for the X-axis (along the length of the table for full 8 feet of travel). You will need to provide some wire to connect the electronics and a computer to run the machine. You will also need to purchase the software that you will need to run the machine that matches how you will apply the machine. We suggest the mach3 control program. The CAM program is up to you as there are many options out there.

    Click the link to respond:
    What does the greenBull kit include and what do I need to include?

  • DOES ZY PLATE COME WITH LASER HEAD COMBO.

    No the ZY plate is part of the machine kit not the head combo kit.

    Click the link to respond:
    DOES ZY PLATE COME WITH LASER HEAD COMBO.

  • DOES THE PRICE OF 2’ X 4’ ROUTER INCLUDE EVERYTHING WOULD NEED TO START ROUTING?

    You will need the following:
    - router/spindle for the machine
    - computer to control the machine
    - construct a table if the optional table is not purchased
    - wire and cable to connect all of the electronics

    Additional Information:
    - software to run the gcode (purchased separately)

    Click the link to respond:
    DOES THE PRICE OF 2’ X 4’ ROUTER INCLUDE EVERYTHING WOULD NEED TO START ROUTING?

  • what is the packing list for the laser/spindle combo head

    The laser/spindle combo head includes the following major items:

    Spindle components:
    - The Spindle and VFD (Variable Frequency Drive) also called an inverter.

    Laser components:
    - 40 watt laser tube.
    - Laser nozzle with laser focus lens (20 mm).
    - nozzle tube fitting with 36 inches of silicone tubing.
    - 40 watt laser power supply.
    - Potentiometer (panel mount) to adjust laser intensity.
    - Toggle switch (on/off SPST - Single Pole Single Throw).
    - Air pump to provide air assist to keep debris out of the nozzle.

    Structure and hardware:
    - All structural parts to form the z-axis rail support and mounts for the spindle and laser tube/nozzle, vacuum hose and dust shoe
    - 1/2" - 10 TPI 5 starts lead screw (2 turns per inch).
    - Many screws/nuts/cross dowels.
    - Dust shoe with installed strip brush.
    - Aluminum angle to serve as rail.

    Click the link to respond:
    what is the packing list for the laser/spindle combo head

  • what does it mean when my spindle VFD inverter shows OC-2?

    Remember, steps to correct and troubleshoot issues with any electrical devices should be done by a professional electrician.

    If you have an HY series VFD, the fault codes are below:

    OC-1: Over-current during ramp up or over-current at constant speed.
    Recommended actions: 1, 2, 3, 4

    OC-1: Over-current during ramp up or over-current at constant speed.
    Recommended actions: 1, 2, 5, 6

    OC-2: Over-current at deceleration or over-current at stop.
    Recommended actions: 1, 7, 2, 9, 10

    dL: Output short circuit.
    Recommended actions: 11, 1, 10

    Ou-1 or 2: Over-voltage at stop, over-voltage at acceleration, over-voltage at constant speed or over-voltage at deceleration
    Recommended actions: 12, 13

    Fb: Fuse break.
    Recommended actions: 14, 10

    Lu: Low voltage.
    Recommended actions: 15, 16, 17

    OH: Over heat of inverter.
    Recommended actions: 18, 19, 20

    OL-1: Inverter overload 150% per minute
    Recommended actions: 2, 21, 22

    OL-2: Motor overload 150% per minute.
    Recommended actions: 21, 23, 24, 25, 26, 21

    dT: Motor over-torque
    Recommended actions: 21, 23

    E.b.S.A or E.b.S.n or E.b.S.d or E.b.S.S: No feedback from the auxiliary coil or the lectromagnetic contactor
    Recommended action: 27

    bt: Braking transistor damage.
    Recommended action: 27

    CPu: CPU fault.
    Recommended action: 27

    E.E.E.S or E.E.E.n or E.E.E.d or E.E.E.A: EEPROM fault
    Recommended action: 27


    List of recommended actions:
    If error shows at ramp up or at constant speed:
    1. Check for a short circuit or partial short circuit and the insulation of the output wire is sufficient.
    2. Increase the capacity or the inverter if it is too small. Replace with an inverter that has a larger capacity
    3. Extend the ramp-up time
    4. Decrease the torque and increase the set value.
    5. Check if the motor is blocked and if there is a sudden change in load.
    6. Check if there is a sudden chance in the power supply voltage.
    7. Extend ramp down time
    9. DC breaking is too high. Decrease DC breaking
    10. Replace the inverter.
    11. Check to see if there is a short circuit with the connection wire of the motor.
    12. Extend the ramp-down time or add a breaking resistor.
    13. Check the mains supply voltage and insure there isn't ant sudden change in voltage.
    14. Send the inverter for repair.
    15. Check whether the input voltage is normal
    16. check whether there is a sudden change in load.
    17. Check whether there is any phase missing.
    18. Check the fan in the inverter. Is it spinning? Is it blocked? Does it have any foreign matter stuck on the fins of the fan? If so, clear the fan.
    19. Check the ambient temperature in the space that the inverter is placed.
    20. Check for adequate ventilation for the inverter where it is placed.
    21. Check for jamming or any sudden change with respect to mechanical load.
    22. Set the V/F curve correctly.
    23. The motor is too small.
    24. The motor is hot and the insulation of the motor degraded.
    25. Check if the voltage has a large variance.
    26. Check if there is a phase missing.
    27. Contact the supplier

    Additional Information:
    I have cnc wood carving machine 1325 the inverter showing error 0006

    Additional Information:
    What is uc3 error

    Additional Information:
    My inverter read error oc-1 high frequency how you can help me please


    Additional Information:
    My inverter read error oc-1 high frequency how you can help me please


    Additional Information:
    203

    Additional Information:
    E2 error

    Additional Information:
    Hello , I have an Redsail cnc and I get the following error " UC3 "after that the spindle stops arter a small knocking sound ,would there be an solution to this ?

    Additional Information:


    Additional Information:
    what does it mean when my spindle VFD shows E o and stops.


    Additional Information:
    Vfd er.01.5c

    Additional Information:
    CPFO error displayed reason

    Click the link to respond:
    what does it mean when my spindle VFD inverter shows OC-2?

  • DOES YOUR COMBO #1 WITH PLANS AND THE DVD COME COMPLETE PARTS LIST?

    The parts list is located on this page: http://buildyourcnc.com/cnckitintro.aspx at the bottom of the description.

    Click the link to respond:
    DOES YOUR COMBO #1 WITH PLANS AND THE DVD COME COMPLETE PARTS LIST?

  • does the skirt come with combo #1

    No the skirt does not come with the kit. Here's a link to where you can buy it https://www.buildyourcnc.com/item/strip-brush.

    Click the link to respond:
    does the skirt come with combo #1

  • Is the 4kv spindle constructed using two or four bearings and what size collets are included with the spindle/vfd combo?

    Yes, all of the spindles come with collets. The collets have a 1/4" (6.35mm) bore for end mills that have a 1/4" shank. The ER specification is different for the 1.5kW (ER-11) and the 2.2kW (ER-20).

    Click the link to respond:
    Is the 4kv spindle constructed using two or four bearings and what size collets are included with the spindle/vfd combo?

  • When will the 2.2kw 110v inverter be in stock?

    It's actually difficult to say when we will get our 2.2kW 110v VFDs (Variable Frequency Drives) in stock. The problem of predicting inventory stock with fluctuating sales is a challenge, especially at the price we offer. Please consider the 220v VFD, even if a 220 outlet is needed to be installed. We have found that the 220v VFD units performance to be better than the 110v VFD units.

    Click the link to respond:
    When will the 2.2kw 110v inverter be in stock?

  • please send wiring diagram for the 1500kw spindle and inverter combo. i need to see what additional things need be purchased. thanks.

    Please refer to the Spindle wiring diagram found on the product page for the 2.2KW spindle. The wiring diagram will be the same for the 1.5kW Spindle. The only difference will depend on if you are using 110v or 220v power, as setting PD008 asks you to specify the max voltage.

    Click the link to respond:
    please send wiring diagram for the 1500kw spindle and inverter combo. i need to see what additional things need be purchased. thanks.

  • wiring the Huajiang yl6000 inverter to mach 3

    1) Acquire a 5 or 6 conductor wire cable of generous length to fit between your Mach30 controller and your VFD (Variable Frequency Drive). The wire gauge should be somewhere between 18GA and 22GA. Maximum current draw will be under 20 milliamps. Cable may also be shielded and/or twisted pairs.
    2) Wire #1 from controller ground to VFD XGND (DC ground)
    4) Wire #2 from controller output defined as (MACH3 output#2) to VFD FWD input
    Note This will give you the ability to start and top the spindle.
    5) Wire #3 from controller analog ground (Speed circuit) to VFD GND.
    6) Wire #4 from controller analog speed output to VFD VI1 (Speed control voltage).
    7) Wire #5 from controller Analog speed 10V or 12V input to VFD 10V or VFD 13V output. (Analog supply voltage).
    8) Program the VFD to accept external start and stop control with front panel STOP.
    9) Program the VFD to accept external analog speed control for zero to ten volts input.
    The above wiring will allow you to start and stop the spindle, and set the spindle speed. You will have control both from G-Code and Mach3 front panel control, including manual On/OFF and percentage control.
    Note: Modbus control is very difficult and fussy to set up, and you lose mach3 front panel manual control.

    Click the link to respond:
    wiring the Huajiang yl6000 inverter to mach 3

  • HOW TO HOOK UP THE VFD INVERTER WALL OUTLET?

    Input to VFD:
    240V Active - R
    240V Neutral - S
    Ground - E

    Click the link to respond:
    HOW TO HOOK UP THE VFD INVERTER WALL OUTLET?

  • What is the rpm range of the 2.2kw spindle and inverter?

    The VFD is capable of a maximum of 400 Hz frequency. That converts to 24,000 RPM for the spindle. The minimum frequency is 100 Hz which is 6000 RPM.

    Additional Information:
    how to program VFD for low speed


    Additional Information:
    You can program the VFD for low RPM only if the spindle will function at low speed without failure. What is the model of your VFD?

    Click the link to respond:
    What is the rpm range of the 2.2kw spindle and inverter?

  • HOW DO YOU HOOK UP THE SPINDLE TO INVERTER?

    U - Pin1
    V - Pin2
    W - Pin3
    Pin4 Dead

    Additional Information:
    My home made cnc is a big problem with my NC connection. When in start my spindle it will be gone wrong. It will be limith switch problem anytime. Need help thanks.

    Click the link to respond:
    HOW DO YOU HOOK UP THE SPINDLE TO INVERTER?

  • WHAT ARE THE OUTPUT INVERTER (VFD) CONNECTIONS TO SPINDLE?

    U - Pin1
    V - Pin2
    W - Pin3
    Pin4 Dead

    Additional Information:
    My home made cnc is a big problem with my NC connection. When in start my spindle it will be gone wrong. It will be limith switch problem anytime. Need help thanks.

    Click the link to respond:
    WHAT ARE THE OUTPUT INVERTER (VFD) CONNECTIONS TO SPINDLE?

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.