Question #: 13669

Question: I have the YL600-2S-2K20 P 110V VFD. I have configured it for using an external source to control the run. According to the enclosed documentation to set to forward run it shows using the X4 terminal. When I use X4 and tell it to run the Rev led lights. If I change to use the X5 terminal it lights the For led. Is your documantation that was included incorrect or do I have something set wrong?

Current Solution

If the spindle runs in the opposite direction than what the VFD shows in the indicator (also when X4 and X5 terminals are used) that sounds like your three wires going to the spindle are incorrect. All you need to do is switch two of the wires and your spindle will run in the correct direction.

Additional Information:
I am still waiting for the cable to connect my spindle so that doesn't come into play yet. I am just looking at the results of the led indicators as being reversed of what the documentation says that I should get by using the X$ and X5 terminals.

Respond:

Other Possible Solutions to this Question

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.