Question: HOW DO YOU CONNECT THE INVERTER TO AC?

Current Solution

Input to VFD:
240V Active - R
240V Neutral - S
Ground - E

Respond:

Other Possible Solutions to this Question

  • HOW TO CONNECT THE SPINDLE INVERTER?

    U - Pin1
    V - Pin2
    W - Pin3
    Pin4 Dead

    Additional Information:
    My home made cnc is a big problem with my NC connection. When in start my spindle it will be gone wrong. It will be limith switch problem anytime. Need help thanks.

    Click the link to respond:
    HOW TO CONNECT THE SPINDLE INVERTER?

  • HOW TO CONNECT THE INVERTER WALL?

    Input to VFD:
    240V Active - R
    240V Neutral - S
    Ground - E

    Click the link to respond:
    HOW TO CONNECT THE INVERTER WALL?

  • HOW DO YOU HOOK UP THE SPINDLE TO INVERTER?

    U - Pin1
    V - Pin2
    W - Pin3
    Pin4 Dead

    Additional Information:
    My home made cnc is a big problem with my NC connection. When in start my spindle it will be gone wrong. It will be limith switch problem anytime. Need help thanks.

    Click the link to respond:
    HOW DO YOU HOOK UP THE SPINDLE TO INVERTER?

  • how connect inverter to usbcard

    We will answer your question but need more specifics as to what you are referring to. Please add additional information and we will respond.

    Additional Information:


    Additional Information:
    Hi, i'm in France, I have an usb breakoutboard from you and a red fly box
    A 2,2 spindle with the correct inverter.
    I just wan't to know if it's possible to drive the spindle from Mach 3,and if it is, how connect the usb card to the inverter which is connected to the spindle.
    Do I need another driver or any interface card?

    Additional Information:


    Additional Information:
    Sorry, I mean with planet cnc not mach3

    Click the link to respond:
    how connect inverter to usbcard

  • how do you connect the power supply to the wall?

    Use an extension cord, cut the female end off, strip off the jacket to expose the white (N), black (L) and green (earth ground). Connect the white to the terminal labeled N. Connect the black wire to the L terminal, and connect the green wire to the terminal with the circle and triangular shaped lines (the terminal that has an earth ground symbol).

    Click the link to respond:
    how do you connect the power supply to the wall?

  • HOW DO YOU SETUP THE SPINDLE INVERTER?

    Change PD001 Source of Run Commands to '1'
    Change PD005 Max operating frequency to 400hz
    Change PD004 base frequency to 400hz
    Change PD003 Main frequency to 400hz
    Change PD006 Intermediate frequency to 2.5
    Change PD008 max voltage to 220v
    Change PD009 Intermediate voltage to 15v
    Change PD010 Min voltage to 8
    Change PD011 frequency lower limit to >100hz (120hz to start)
    Change PD142 7 Amps
    Change PD143 2
    Change PD144 3000

    Note: PD001 had to be changed back to 0 to allow for keypad control.
    Note2: I had to reverse U and V to get the spindle to go forward in FWD. (reverse any two wires, u&v or w&v for example)

    Click the link to respond:
    HOW DO YOU SETUP THE SPINDLE INVERTER?

  • WHAT ARE THE OUTPUT INVERTER (VFD) CONNECTIONS TO SPINDLE?

    U - Pin1
    V - Pin2
    W - Pin3
    Pin4 Dead

    Additional Information:
    My home made cnc is a big problem with my NC connection. When in start my spindle it will be gone wrong. It will be limith switch problem anytime. Need help thanks.

    Click the link to respond:
    WHAT ARE THE OUTPUT INVERTER (VFD) CONNECTIONS TO SPINDLE?

  • HOW DO YOU SETUP THE SPINDLE INVERTER VFD?

    Change PD001 Source of Run Commands to '1'
    Change PD005 Max operating frequency to 400hz
    Change PD004 base frequency to 400hz
    Change PD003 Main frequency to 400hz
    Change PD006 Intermediate frequency to 2.5
    Change PD008 max voltage to 220v
    Change PD009 Intermediate voltage to 15v
    Change PD010 Min voltage to 8
    Change PD011 frequency lower limit to >100hz (120hz to start)
    Change PD142 7 Amps
    Change PD143 2
    Change PD144 3000

    Note: PD001 had to be changed back to 0 to allow for keypad control.
    Note2: I had to reverse U and V to get the spindle to go forward in FWD. (reverse any two wires, u&v or w&v for example)

    Click the link to respond:
    HOW DO YOU SETUP THE SPINDLE INVERTER VFD?

  • WHAT TERMINALS ARE USED TO CONNECT THE INVERTER WALL OUTLET?

    Input to VFD:
    240V Active - R
    240V Neutral - S
    Ground - E

    Click the link to respond:
    WHAT TERMINALS ARE USED TO CONNECT THE INVERTER WALL OUTLET?

  • How do you connect the spindle VFD to the parallel breakout board

    The parallel board contains a relay that is connected to pin #16. You can use this relay as the start/stop by connecting the relay to the FOR and it's related digital GND pin on the VFD.

    Additional Information:


    Additional Information:


    Additional Information:

    Click the link to respond:
    How do you connect the spindle VFD to the parallel breakout board

  • WHAT ARE THE SPINDLE INVERTERS (VFD) INPUT AC CONNECTIONS FROM WALL OUTLET?

    Input to VFD:
    240V Active - R
    240V Neutral - S
    Ground - E

    Click the link to respond:
    WHAT ARE THE SPINDLE INVERTERS (VFD) INPUT AC CONNECTIONS FROM WALL OUTLET?

  • do you have a 4 pin male connector with the wires attached?

    Yes and properly soldered.

    Additional Information:
    20

    Click the link to respond:
    do you have a 4 pin male connector with the wires attached?

  • WHAT ELECTRICAL CABLE DO I USE TO CONNECT VFD INVERTER SPINDLE?

    The type of wire that should be used between the spindle and the VFD (Variable Frequency Driver also called the inverter) should be of stranded type and we use between 18 and 16 AWG.

    The total current is divided among the three coil wires, therefor a wire gauge of 16 should be sufficient.

    Currently we use 20AWG 4 conductor.

    Additional Information:

    Click the link to respond:
    WHAT ELECTRICAL CABLE DO I USE TO CONNECT VFD INVERTER SPINDLE?

  • How do I connect a Z-Axis touch plate to the Planet-CNC USB interface?

    "Semi automatic" measuring is possible.
    1. Place movable tool sensor (touch plate) on material.
    2. Click "Measure Offset Z". Tool will move down, touch sensor and move up.
    3. "Measure Offset Z" button is still down.
    4. Click "Offset - Current Z" - this will set offset Z
    5. Click "Measure Offset Z" again to release it and restore normal mode."

    The connections to the USB interface is as follows:
    - The spindle is connected to the gnd terminal (which is also connected to the end mill). Alternatively, you can connect the gnd directly to the end mill is access is permitted.
    - The touch plate (movable tool sensor) is connected to the Z-- terminal.

    What will happen: When the end mill (gnd) is in contact with the touch plate (Z--), there will be a connection from gnd to the Z-- triggering this Z-- action and the software will recognize the connection (like a button press, or a limit switch triggering).

    Additional Information:


    Additional Information:

    Click the link to respond:
    How do I connect a Z-Axis touch plate to the Planet-CNC USB interface?

  • How do I connect a heated bed to the whiteant

    Connecting a heater bed to the whiteAnt is currently unavailable with our current version electronics, as we have tried to get around that issue here! We do not have the available slot for another thermocouple, so reading the temperature will not be possible for the heater bed. Also doubling the heater bed and extruder is not recommended, in which our current electronics will not be able to work with the additional heater bed.

    Click the link to respond:
    How do I connect a heated bed to the whiteant

  • How do I connect my motor wires to the driver?

    Use the datasheet associated to the motor that you purchased. Use the bipolar parallel configuration to optimum performance. The datasheets are located in their respective motor product pages. Just click on the motion electronics at the left and scroll down to the motor you have and click on the title, or datasheet link next to the motor. The datasheet will either be in the form of a pdf, or within the instructions on that product page.

    Additional Information:
    wiring diagram

    Click the link to respond:
    How do I connect my motor wires to the driver?

  • How should I connect the E-stop to the machine?

    I would recommend wiring the E-Stop to an input terminal via an NC connection. This is the industry standard. It requires a NC (Normally connected) circuit for the machine to be operational, and when the circuit breaks, the machine shuts off. This is better than having a circuit NO (normally open), open circuit that requires a circuit to be created to have the machine shut off for safety.

    Having en E-Stop run through the mains line would only work for a single circuit (or use multiple E-stops, which defeats the purpose). The E-stop connected to the input terminal would shut off all machine functions.

    Click the link to respond:
    How should I connect the E-stop to the machine?

  • HOW DO I CONNECT A TOUCH PLATE TO THE BREAKOUT BOARD?

    The instructions on how to do this are found here, in these two videos, http://buildyourcnc.com/PrimeronHomingandLimitSwitches.aspx

    Click the link to respond:
    HOW DO I CONNECT A TOUCH PLATE TO THE BREAKOUT BOARD?

  • Using the PoKeys57CNC how to you connect two motors to the Y axis and how is Mach 4 configured for this?

    Polabs prepared step by step user guide for PoKeys57CNC and Mach4 to try answering such questions. It is available in our downloads section: https://www.poscope.com/wp-content/uploads/downloads/Pokeys/LibrariesAndPlugins/Mach4 and PoKeys57CNC - step by step guide.pdf

    Click the link to respond:
    Using the PoKeys57CNC how to you connect two motors to the Y axis and how is Mach 4 configured for this?

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.