Question: The instructions for the 3-axis combo at https://buildyourcnc.com/item/electronicsAndMotors-3axis-425-elcombo seem to be missing. Can you look into that.

Current Solution

To wire the CNC electronics, use the tutorial for the specific interface board you are using.

If you have the parallel breakout board, use this tutorial:
https://buildyourcnc.com/CNCElectronicsandWiring.aspx

If you have the USB interface board, use this tutorial:
https://buildyourcnc.com/tutorials/tutorial-Electronics-USB-Interface-Wiring

Additional Information:



Additional Information:



Additional Information:

Respond:

Other Possible Solutions to this Question

  • DO NEED TO SQUARE UP THE MACHINE AND IF SO YOU HAVE INSTRUCTIONS OR VIDEO FOR THIS?

    The eyebolts are used in the squaring of the machine. I would use a standard carpenters square and first run the end mill along the edge of the square to first make it parallel with the long axis. Then run the end mill along the other edge with the short axis and adjust the eye bolts and chain according to the angle that the machine is out of square.

    Additional Information:

    Click the link to add information to this solution:
    DO NEED TO SQUARE UP THE MACHINE AND IF SO YOU HAVE INSTRUCTIONS OR VIDEO FOR THIS?

  • HOW DO I WIRE THE 4TH AXIS THAT YOU SELL. I HAVE MACH3 SOFTWARE. NO INSTRUCTIONS ON YOUR SITE

    The motor that is attached to the 4th axis is wired as follows:

    The motor should have red, green yellow and blue wires coming form the motor. The red and green are paired as one coil and the yellow and blue is paired as the other coil. You can wire the motor to a 3.0 amp driver with red to A+, green to A-, Yellow to B+ and Blue to B-

    Click the link to add information to this solution:
    HOW DO I WIRE THE 4TH AXIS THAT YOU SELL. I HAVE MACH3 SOFTWARE. NO INSTRUCTIONS ON YOUR SITE

  • I AM INTERESTED IN THE 3 AXIS COMBO USB OPTION. NOTICE YOU ENDORSE PLANET-CNC FOR USE WITH THIS BUT WILL MACH3 INTERFACE WELL BEAK OUT BOARD?
  • WHERE ARE THE WIRING DIAGRAMS FOR BLACKTOOTH LASER CUTTER IN INSTRUCTIONS?

    You can find the wiring diagrams for the blackTooth on step 105 and 106 on the list of instructions on the blackTooth page. Step 105 pertains to the parallel breakout board and step 106 pertains to the USB interface board.

    Additional Information:
    wire size

    Click the link to add information to this solution:
    WHERE ARE THE WIRING DIAGRAMS FOR BLACKTOOTH LASER CUTTER IN INSTRUCTIONS?

  • ARE THERE PRODUCTS AVAILABLE TO THE GENERAL PUBLIC THAT CAN BE PURCHASED PROTECT CELLULAR OR PORTABLE TELEPHONE USERS FROM RADIATION? IF SO, WHERE THESE FOUND?

    There are a number of opportunistic gadgets on the market to allegedly protect the user from hazards of cellular phones. You can search the Internet to find the latest, ranging from antenna shields to whole-body shielding materials. Most experts believe that these devices take advantage of customers' misunderstanding and unfounded fears to sell products with no real value. First of all, cell phones that operate within the guidelines established by national and international safety panels have never been shown to pose a health risk to the user (see answers to other questions on cell phone safety on this website). Secondly, placing any kind of shield over the antenna of a cell phone will in most cases cause it to increase its RF output as it attempts to compensate for signal loss in the shield and maintain a quality phone call. The U.S. Food and Drug Administration published an advisory on cell phones several years ago that said if you are concerned about risks of using a cell phone, then simply use it less. That is still good advice today. Gary Zeman, ScD, CHP Lawrence Berkeley National Laboratory

    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    ARE THERE PRODUCTS AVAILABLE TO THE GENERAL PUBLIC THAT CAN BE PURCHASED PROTECT CELLULAR OR PORTABLE TELEPHONE USERS FROM RADIATION? IF SO, WHERE THESE FOUND?

  • CAN YOU PLEASE TELL ME THE AVAILABILITY OF 12X36 BLUE CHICK 4.2, AND COST FOR SHIPPING TO ZIP 72802 IN RUSSELLVILLE, ARKANSAS?

    Yes, the blueChick kits are available. You can get the shipping rates automatically in the shopping cart. There will be a calculate shipping button on the enter shipping information section of the shopping cart.

    Click the link to add information to this solution:
    CAN YOU PLEASE TELL ME THE AVAILABILITY OF 12X36 BLUE CHICK 4.2, AND COST FOR SHIPPING TO ZIP 72802 IN RUSSELLVILLE, ARKANSAS?

  • MY QUESTION THAT KNOW CANCER CAN BE CAUSED WHEN OUR BODY EXPOSED TO DOSES OF 50 CGY OR HIGHER. WHAT DOES STAND FOR? DO EMIT?

    The term cGy (centigray) is a unit of absorbed dose of ionizing radiation such as x rays or gamma rays. Cell phones do not emit ionizing radiation. They emit nonionizing radiation, namely radiofrequency (RF) energy. Absorption of nonionizing radiation in the body is measured in terms of the specific absorption rate (SAR) in units of watts per kilogram. Both ionizing and nonionizing radiation are forms of electromagnetic energy. The difference is that ionizing radiation has sufficient energy per photon to cause ionization of molecules. Nonionizing radiation does not. It is the ionizing effect of ionizing radiation that has been linked to increased risk of cancer. For more information on cell phones and health check out a Medical College of Wisconsin website. For more information on ionizing versus nonionizing radiation check out a University of Michigan website. Gary Zeman, ScD, CHP Lawrence Berkeley National Laboratory

    Click the link to add information to this solution:
    MY QUESTION THAT KNOW CANCER CAN BE CAUSED WHEN OUR BODY EXPOSED TO DOSES OF 50 CGY OR HIGHER. WHAT DOES STAND FOR? DO EMIT?

  • WE ARE ALWAYS CONCERNED THAT THERE WON'T BE ENOUGH VACCINE TO VACCINATE OUR PATIENTS IN THE FALL. WHAT CAN DO ASSURED WE'VE DONE ALL POSSIBLY AVOID THIS TYPE OF SITUATION?

    It is never too early to begin planning for the coming fall's influenza vaccination program. The most important thing you can do initially is to place your order for vaccine from your usual source. Some manufacturers often stop taking pre-orders in mid-May. Be sure to include vaccine for pediatric patients needing two doses and also for your facility's healthcare workers as part of your overall campaign.

    Click the link to add information to this solution:
    WE ARE ALWAYS CONCERNED THAT THERE WON'T BE ENOUGH VACCINE TO VACCINATE OUR PATIENTS IN THE FALL. WHAT CAN DO ASSURED WE'VE DONE ALL POSSIBLY AVOID THIS TYPE OF SITUATION?

  • CAN YOU GIVE ME SOME HELP OR POINT IN THE RIGHT DIRECTION TO INCORPORATE MK 7 EXTRUDER WITH BOOK PLANS FOR 3D PRINTER?

    Mounting the extruder to the whiteAnt can be done a couple of ways. One is to take the 4 mounting holes located at the lower portion of the z-axis rail support and use long screws protruding out. Take a thinner material and drill the four holes matching the locations of the 4 screws and screw on nuts to hold it in place. The other option would be to use the metal bracket and fasten to the edge of the rail support.

    Click the link to add information to this solution:
    CAN YOU GIVE ME SOME HELP OR POINT IN THE RIGHT DIRECTION TO INCORPORATE MK 7 EXTRUDER WITH BOOK PLANS FOR 3D PRINTER?

  • HOW CAN I DETERMINE THE DOSE EQUIVALENT (MREM/HR, MREM/WK, MREM/YR) USING RAW DATA FROM A TLD (THERMOLUMINESCENT DOSIMETER) THAT WAS PLACED IN AN OFFICE FOR 22 DAYS?

    Assumption 1: The "raw data" of 24 mrem on the TLD is the total dose received by the TLD during the 22 days that the TLD was deployed in your office. This means that (1) any TLD reader background signal has been properly subtracted, (2) the signal accumulating in the TLD during any transport or storage time between preparation (annealing) and deployment in your office has been properly subtracted and, (3) the signal accumulating in the TLD during any transport or storage time between removal from your office and processing (reading) has been properly subtracted.

    With this assumption, the total dose rate in your office is (24 mrem)/(22 days), or 1.091 mrem per day. The reference background is given as 63 mrem per year which is (63 days)/(365.25 days per year) or 0.172 mrem per day. Thus the average net dose rate to the TLD during the 22 days was (1.091-0.172) = 0.919 mrem per day.

    Assumption 2: The net dose rate of 0.919 mrem per day in your office is attributable to the accelerator or other regulated sources under the control of your institution.

    Assumption 3: The office occupancy factor of 1/4 attributed in your question to NCRP Report 49 was misread from Table 4. The correct occupancy factor given in NCRP 49 for offices is 1.

    Assumption 4: You take 20 business days per year off for vacation and holidays. You work in your office for the remaining 240 days per year.

    Assumption 5: All of the accelerator shots occur while you are in your office.

    Assumption 6: The average net dose rate of 0.919 mrem per day determined during the 22 days of measurement continues for a year.

    Based on the data that you provided and my assumptions, your annual dose received in your office from the accelerator or other regulated sources at your institution is predicted to be (0.919 mrem per day) x (240 work days per year) = 220 mrem.

    Tom Gesell, PhD

    Click the link to add information to this solution:
    HOW CAN I DETERMINE THE DOSE EQUIVALENT (MREM/HR, MREM/WK, MREM/YR) USING RAW DATA FROM A TLD (THERMOLUMINESCENT DOSIMETER) THAT WAS PLACED IN AN OFFICE FOR 22 DAYS?

  • I HAVE YOUR MACH3 USB BOB, DO YOU GUYS SELL A TORCH CONTROL RELAY CAN WIRE UP TO TURN MY PLASMA ON AND OFF HOW WOULD WIFE THAT TOO THIS BOB?

    We do have a relay board that words like a standard relay.

    Here is the URL of the relay board that we offer:

    https://www.buildyourcnc.com/item/electronicsAndMotors-breakout-Relays-relay-board-250V-12A-5V

    Click the link to add information to this solution:
    I HAVE YOUR MACH3 USB BOB, DO YOU GUYS SELL A TORCH CONTROL RELAY CAN WIRE UP TO TURN MY PLASMA ON AND OFF HOW WOULD WIFE THAT TOO THIS BOB?

  • IT MORE DANGEROUS STAY FOR ONE HOUR AT A TEN-METER DISTANCE FROM CELLULAR ANTENNA OR TALK INTO PHONE THE SAME AMOUNT OF TIME?

    Cellular phones are designed to be safe for both the user and anyone standing nearby. Cellular phones are actually small radios that transmit signals to and from base-station antennas located on towers or buildings in the nearby neighborhood. Cellular phones use low-power radio signals, even weaker than CB, police, or fire radios.

    The American National Standards Institute (ANSI) sets safety standards for human exposure to radiofrequency (RF) electromagnetic energy in the United States. Government agencies such as the Federal Communications Commission (FCC), the Occupational Safety and Health Administration (OSHA), and many states recognize and accept the ANSI RF safety standard. Also, the United States standard for RF energy is comparable to those set in other countries.

    Cellular phones and cellular-phone base stations have been shown to meet these RF safety standards. Safety standards for RF energy are threshold standards. Threshold standards define the level of RF energy above which there may be health or safety hazards and below which there have been no reported harmful effects. Unlike ionizing radiation, which many people believe to act cumulatively even at small exposure levels, RF energy at low levels is not considered a cumulative hazard. Therefore the consensus of scientific experts in this area is that RF exposure from cellular phones, meeting the threshold levels set in safety standards, is safe for all.

    The specific answer to the question is that cellular phone technology is safe for all. There is no danger posed by either handheld phone units or by base-station antennas. In both cases, the radio signals transmitted from the antennas are required to meet the ANSI safety standard for RF safety as embodied in FCC regulations governing this technology. For more information:

    The FCC has recently revised and reissued its Bulletin 56 on Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields.

    OSHA provides information and links to more sites on RF safety at its Web page, Radiofrequency/Microwave Radiation.

    Gary Zeman, ScD, CHP Lawrence Berkeley National Laboratory

    Click the link to add information to this solution:
    IT MORE DANGEROUS STAY FOR ONE HOUR AT A TEN-METER DISTANCE FROM CELLULAR ANTENNA OR TALK INTO PHONE THE SAME AMOUNT OF TIME?

  • I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to add information to this solution:
    I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

  • AM NOT SURE HOW TO SET THE Z AXIS TURN ON/OFF LASER WHEN CREATE CODE. KNOW THAT ITS TYPICALLY Z-AXIS MOVEMENT DOES THIS - BUT YOU DONT SHOW ANYTHING HOOKED UP IN PLACE OF AXIS.

    When the z axis is going down, the laser turns on. When the z axis is going up, it turns off. The z axis directions is only a signal that is either 5v or 0v. That determines the direction. In vectric, you will need to set your machining operations with a very very small depth so the time it takes to get to its final depth is a very short time.

    Click the link to add information to this solution:
    AM NOT SURE HOW TO SET THE Z AXIS TURN ON/OFF LASER WHEN CREATE CODE. KNOW THAT ITS TYPICALLY Z-AXIS MOVEMENT DOES THIS - BUT YOU DONT SHOW ANYTHING HOOKED UP IN PLACE OF AXIS.

  • THEY ARE ASKING FOR THE ACTIVATION CODE AND SERIAL NUMBER USB BOARD. HOW CAN GET THAT INFORMATION?

    To get the activation code, all you need to do is plug the USB board into the computer using a USB cable, go to machine -> firmware -> update. After the firmware is updated the program will present to you a dialog box containing the activation code.

    Additional Information:
    MUAR-QVXU-CAYW-CBWQ


    Additional Information:
    MUIS-RQPB-PTHB-QTTB

    Additional Information:
    MUIH-EERP-IADB-TRIP

    Additional Information:
    9zYWBVf5TxKSK7hEr8gFX3EBw5wa0AMMllQqgftIAnKvZ8DXItLxaPbOB3jWvnpczl/sM/De0scRPHfSxWGmcA==

    Additional Information:
    Key: LUQR-BQYI-SCEW-QVBT

    Additional Information:


    Additional Information:
    after i copy the code in the lower case i recived the same message (more than 8 times) ,, this is a evaluation...,, what i need to do to register properly?

    Additional Information:
    MUJR-BISM-KRDN-KKER
    056971

    Additional Information:
    0561234

    Additional Information:
    MURL-QPQU-EGBJ-FNMB

    Additional Information:
    MUCE-LFMQ-WBCW-MLHO

    Additional Information:


    Additional Information:
    LUTA-ADVJ-FXTW-FBCE

    Additional Information:
    LUTA-ADVJ-FXTW-FBCE

    Additional Information:
    looking for registration key for MUUK-IBTW-ECTL-CJWD

    Additional Information:
    MUXO-PIYY-KNHD-RKLY

    Additional Information:
    MUUE-YYCR-FCIC-VATK

    Additional Information:
    MUUE-YYCR-FCIC-VATK

    Additional Information:


    Additional Information:
    MUEY-YLJU-OBRR-LJBV

    Additional Information:
    MUSP-JFDV-EKGQ-OVLW

    Additional Information:
    MUSP-JFDV-EKGQ-OVLW

    Additional Information:


    Additional Information:


    Additional Information:
    MULY-XRYF-BBDN-FBWP

    Additional Information:


    Additional Information:


    Additional Information:
    how to generate activation code richauto a11

    Additional Information:
    MUJC-LNIL-EOHS-YKNQ

    Additional Information:
    sdfd

    Additional Information:
    m l

    Additional Information:
    MUXC-RWKB-PKAL-HGNN

    Additional Information:
    57625YY60Y7Y30X5

    Additional Information:
    57625YY60Y7Y30X5

    Additional Information:
    57625YY60Y7Y30X5

    Additional Information:
    57625YY60Y7Y30X5

    Click the link to add information to this solution:
    THEY ARE ASKING FOR THE ACTIVATION CODE AND SERIAL NUMBER USB BOARD. HOW CAN GET THAT INFORMATION?

  • IT POSSIBLE TO BUY THE CAD FILES FOR BLACK FOOT MACHINE, MECHANICAL PARTS AND ELECTRONICS BUT NOT WOODEN PARTS, SAVE SHIPPING COSTS? IN THAT CASE I WOULD INSTRUCT SOMEONE MILL ME.

    The files and hardware option for our machines has been removed from the site due to the following reasons:
    Difficulty for the end use of the files and the challenges (and time/money) on our side to assist in using these files.
    The abuse of these files over the internet.
    Ultimately may reduce the sales of machines keeping us in business.
    Sadly, this is what has come out of our company attempting to be open; however, the machines sold on this site is still far lower in price than the competition for the quality that we provide as we have a great desire to engender the cottage industry to fulfill their need for low end manufacturing. My sincere apologies if this causes any inconvenience.

    Additional Information:
    NO, is not possible, I can help with the shipping cost

    Additional Information:

    Click the link to add information to this solution:
    IT POSSIBLE TO BUY THE CAD FILES FOR BLACK FOOT MACHINE, MECHANICAL PARTS AND ELECTRONICS BUT NOT WOODEN PARTS, SAVE SHIPPING COSTS? IN THAT CASE I WOULD INSTRUCT SOMEONE MILL ME.

  • IS THE CNC MACHINE HARDWARE & PLANS COMBO SHOWN AT LINK YOU LISTED SAME DESCRIBED IN BOOK?

    Yes, the CNC machine hardware and plans combo is the same machine as in the book. The machine that we provide the plans for, can be found on the website, here http://buildyourcnc.com/Item/cnc-machine-scratchbuild

    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    IS THE CNC MACHINE HARDWARE & PLANS COMBO SHOWN AT LINK YOU LISTED SAME DESCRIBED IN BOOK?

  • WE'VE HEARD THAT ACIP HAS LIMITED THE USE OF ONE INFLUENZA VACCINE PRODUCTS FOR CHILDREN BEGINNING WITH 2010-11 VACCINATION SEASON. TRUE?

    Yes. You are referring to Afluria, which is manufactured in Australia by CSL Laboratories for the U.S. market. CSL's 2010 Southern Hemisphere influenza vaccine (Fluvax and Fluvax Junior) has been associated with increased post-marketing reports of fever and febrile seizures in children predominantly younger than age 5 years as compared to previous years. For this reason, on August 5, 2010, ACIP recommended that Afluria, 0.5 mL, licensed for use in people age 36 months and older, not be used in children younger than age 9 years. ACIP further recommended that Afluria could be administered to children ages 5 through 8 years who are at high risk for influenza complications if there is no other age-appropriate TIV available, after risks and benefits of using this vaccine in this age group have been discussed with the parent or guardian. The vaccine should not be given to children younger than age 5 years. For detailed information, go to www.cdc.gov/media/pressrel/2010/s100806.htm.

    Click the link to add information to this solution:
    WE'VE HEARD THAT ACIP HAS LIMITED THE USE OF ONE INFLUENZA VACCINE PRODUCTS FOR CHILDREN BEGINNING WITH 2010-11 VACCINATION SEASON. TRUE?

  • I HAVE NOT SEEN ANY REFERENCES TO STEPPING MOTOR ENCODER FEED-BACK FOR CLOSED LOOP CAPABILITY IN OF THE HARDWARE YOU SELL. THIS A SUPPORTED FEATURE WITH HARDWARE/SOFTWARE SELL?

    I haven't delved into using encoders with stepping motors too much. From my research, you need to have a controller that can provide the closed loop control, rather than software handling that process. I have also found from my research that using encoders on stepping motors is generally used to stop the machine in the case that the motor failed to achieve the commanded position for some reason and gives the user the chance to correct and continue with the job.

    If you want proper closed loop control, it may be best to go with servos and servo controller that provide the closed loop control within the real of those two components.

    Click the link to add information to this solution:
    I HAVE NOT SEEN ANY REFERENCES TO STEPPING MOTOR ENCODER FEED-BACK FOR CLOSED LOOP CAPABILITY IN OF THE HARDWARE YOU SELL. THIS A SUPPORTED FEATURE WITH HARDWARE/SOFTWARE SELL?

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.