My limit switches keep tripping a reset. Wiring all seems right. Could there be another cause I can check?
Share
http://buildyourcnc.com/PrimeronHomingandLimitSwitches.aspx There is a pin setting in Mach3 that says how to react to the inputs from the switches. Your setting is probably wrong as the trigger happens immediately. You may want to think about shielded wire and/or a resistor on each limit switch line. If there are stray wires, connect them to ground. Additionally, the shield from the shielded cable insulation should alse connected to ground at both ends. Try upping the Debounce interval in Mach3. You have to adjust the debounce interval. You go to config,general config, and it is in the top right corner. I set mine to 100 and it seems to work well. Additional Information: how to solution cnc revo 540 limit tripped error? Additional Information: Additional Information: Additional Information: