Question: What is the rpm range of the 2.2kw spindle and inverter?

Current Solution

The VFD is capable of a maximum of 400 Hz frequency. That converts to 24,000 RPM for the spindle. The minimum frequency is 100 Hz which is 6000 RPM.

Respond:

Other Possible Solutions to this Question

  • I would like to know what the lowest rpm that can be acheived with the 2.2kw spindle and inverter and still have enough torque to drill

    According to the supplier of the 2.2 kW spindle, the safest operating speed for the spindle is 6000 RPM. The supplier also stated that theoretically, the spindle can operate from 0 to 24,000 RPM. I am continuing a dialog with the supplier to delve deeper into understanding the configurations and ramifications of such configurations for operations outside of the safe boundaries into the "theoretical" ranges.

    Additional Information:
    20

    Click the link to respond:
    I would like to know what the lowest rpm that can be acheived with the 2.2kw spindle and inverter and still have enough torque to drill

  • How to display RPM instead of frequency on the VFD? I have the 2.2kv 110 volt spindle and inverter.

    There is a button on the front of the VFD that will cycle through RPM, Freq, and a few other readings. If there is a >> button on your VFD, that will work. If there is a mode button on your VFD, that should works as well.

    Additional Information:
    There is a >> disc button but it does not cycle through the display modes.

    Additional Information:
    Is there a parameter setting to make this button work to cycle thru the display modes?

    Click the link to respond:
    How to display RPM instead of frequency on the VFD? I have the 2.2kv 110 volt spindle and inverter.

  • What all is included in the GreenLean kit (sold with RedSprout and spindle/inverter)?

    The greenLean with the redSprout and the spindle option has everything you need excluding the spoilboard and the end mill.

    Click the link to respond:
    What all is included in the GreenLean kit (sold with RedSprout and spindle/inverter)?

  • What are the noise levels of the 1.5 Kw and 2.2Kw spindles?

    The noise level of the 1.5 kW and the 2.2 kW are very similar. The noise level is considerably quieter than typical routers. I am going to add sound db levels to this FAQ a bit later.

    Additional Information:
    The db (decibels) reading for the spindle is 70 and an 890 Porter Cable router (a lower powered tool than the spindle) measured 90 db. Both measurements were taken in the same environment and measured at the same distance from the tool.

    Additional Information:
    Practically silent. The inverter makes more noise!

    Additional Information:
    Practically silent. The inverter makes more noise!

    Click the link to respond:
    What are the noise levels of the 1.5 Kw and 2.2Kw spindles?

  • what is the warranty period and do you repair these in house? 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)

    Spindles are generally covered up to 1 year after date of purchase. We do not repair them in house, but we do work with our manufacturer to replace defective units. Generally if you have a defective unit covered under warranty, we will issue a replacement.

    Click the link to respond:
    what is the warranty period and do you repair these in house? 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)

  • Is a 110v 20a circuit sufficient to run the spindle (2.2kw w/110v inverter)?

    t might be a better idea to increase the circuit breaker above 20 as 2200/110 is exactly 20. You will not have a buffer there in case you need it. Alternatively, you can decrease the current draw of the spindle in the VFD programming process.

    Click the link to respond:
    Is a 110v 20a circuit sufficient to run the spindle (2.2kw w/110v inverter)?

  • WHAT ARE THE OUTPUT INVERTER (VFD) CONNECTIONS TO SPINDLE?

    U - Pin1
    V - Pin2
    W - Pin3
    Pin4 Dead

    Additional Information:
    My home made cnc is a big problem with my NC connection. When in start my spindle it will be gone wrong. It will be limith switch problem anytime. Need help thanks.

    Click the link to respond:
    WHAT ARE THE OUTPUT INVERTER (VFD) CONNECTIONS TO SPINDLE?

  • on the 2.2Kw water cooled spindle, what is the cooling port thread type and size?

    It is an M8 metric size on the port going into the spindle, and a 1/4" compression on the other side.

    Is the M8 port a M8x1.25 or M8x1?

    If you are referring to the book build, use a chamfer bit that is large enough to create a chamfer for most of the edge of the 3/4" thickness of the board, but still has a sliver of space for the bearing on which to ride.

    Additional Information:
    Mine is M8x1mm. I replaced the stock fitting with a brass hose barb and used "steel wire reinforced vacuum hose" with a 1/4" ID because it resists kinking and collapsing.

    Click the link to respond:
    on the 2.2Kw water cooled spindle, what is the cooling port thread type and size?

  • What is the liquid input and output barb size on your 2.2kw water cooled spindle?

    The spindle water inlet and outlet fittings are 1/4 Inside Diameter and 3/8 Outside Diameter.

    You can find the silicone tubes here:
    https://buildyourcnc.com/item/pneumatic-hydraulic-silicone-tubing

    This fitting will connect to the pump (1/2" male to 1/4" female):
    https://buildyourcnc.com/item/pneumatic-hydraulic-Tube-Fitting-Female-to-Male

    And this fitting will provide a reduced barbed size (1/4") for the tube:
    https://buildyourcnc.com/item/pneumatic-hydraulic-Tube-Fitting-Barbed-to-Male

    Click the link to respond:
    What is the liquid input and output barb size on your 2.2kw water cooled spindle?

  • What is the HP of the 2.2KW spindle

    The 2.2kW spindle outputs approximately 3 HP (Horse Power).

    Click the link to respond:
    What is the HP of the 2.2KW spindle

  • WHAT ARE THE SPINDLE INVERTERS (VFD) INPUT AC CONNECTIONS FROM WALL OUTLET?

    Input to VFD:
    240V Active - R
    240V Neutral - S
    Ground - E

    Click the link to respond:
    WHAT ARE THE SPINDLE INVERTERS (VFD) INPUT AC CONNECTIONS FROM WALL OUTLET?

  • please send wiring diagram for the 1500kw spindle and inverter combo. i need to see what additional things need be purchased. thanks.

    Please refer to the Spindle wiring diagram found on the product page for the 2.2KW spindle. The wiring diagram will be the same for the 1.5kW Spindle. The only difference will depend on if you are using 110v or 220v power, as setting PD008 asks you to specify the max voltage.

    Click the link to respond:
    please send wiring diagram for the 1500kw spindle and inverter combo. i need to see what additional things need be purchased. thanks.

  • What is the warranty on your 2.2KW spindle

    We honor a one year warranty on most parts like main machine components, structural parts, mechanical parts and some electronic parts including spindles.

    Click the link to respond:
    What is the warranty on your 2.2KW spindle

  • hi, would like to make a change on my order, i purchase this part 2.2kW Spindle with 220V Inverter $528.00, and would like to make it for 110 volts instead of 220v. please

    Sure, not a problem at all. You will need to call our office and provide your information so that we can change the correct order.

    Our phone number can be seen by hovering over the "Need Help?" at the top right of each page.

    Click the link to respond:
    hi, would like to make a change on my order, i purchase this part 2.2kW Spindle with 220V Inverter $528.00, and would like to make it for 110 volts instead of 220v. please

  • 2.2kW Spindle with 110V Inverter, can I get a collet for 1/2 router bits for this spindle

    Absolutely. You can have 1/2" collets used in 2.2kW spindles.

    Here is a link for the ER-20 1/2"ID Collet:
    https://www.buildyourcnc.com/item/spindle-collet-!5-er20-spindle-collet

    Click the link to respond:
    2.2kW Spindle with 110V Inverter, can I get a collet for 1/2 router bits for this spindle

  • what does it mean when my spindle VFD inverter shows OC-2?

    Remember, steps to correct and troubleshoot issues with any electrical devices should be done by a professional electrician.

    If you have an HY series VFD, the fault codes are below:

    OC-1: Over-current during ramp up or over-current at constant speed.
    Recommended actions: 1, 2, 3, 4

    OC-1: Over-current during ramp up or over-current at constant speed.
    Recommended actions: 1, 2, 5, 6

    OC-2: Over-current at deceleration or over-current at stop.
    Recommended actions: 1, 7, 2, 9, 10

    dL: Output short circuit.
    Recommended actions: 11, 1, 10

    Ou-1 or 2: Over-voltage at stop, over-voltage at acceleration, over-voltage at constant speed or over-voltage at deceleration
    Recommended actions: 12, 13

    Fb: Fuse break.
    Recommended actions: 14, 10

    Lu: Low voltage.
    Recommended actions: 15, 16, 17

    OH: Over heat of inverter.
    Recommended actions: 18, 19, 20

    OL-1: Inverter overload 150% per minute
    Recommended actions: 2, 21, 22

    OL-2: Motor overload 150% per minute.
    Recommended actions: 21, 23, 24, 25, 26, 21

    dT: Motor over-torque
    Recommended actions: 21, 23

    E.b.S.A or E.b.S.n or E.b.S.d or E.b.S.S: No feedback from the auxiliary coil or the lectromagnetic contactor
    Recommended action: 27

    bt: Braking transistor damage.
    Recommended action: 27

    CPu: CPU fault.
    Recommended action: 27

    E.E.E.S or E.E.E.n or E.E.E.d or E.E.E.A: EEPROM fault
    Recommended action: 27


    List of recommended actions:
    If error shows at ramp up or at constant speed:
    1. Check for a short circuit or partial short circuit and the insulation of the output wire is sufficient.
    2. Increase the capacity or the inverter if it is too small. Replace with an inverter that has a larger capacity
    3. Extend the ramp-up time
    4. Decrease the torque and increase the set value.
    5. Check if the motor is blocked and if there is a sudden change in load.
    6. Check if there is a sudden chance in the power supply voltage.
    7. Extend ramp down time
    9. DC breaking is too high. Decrease DC breaking
    10. Replace the inverter.
    11. Check to see if there is a short circuit with the connection wire of the motor.
    12. Extend the ramp-down time or add a breaking resistor.
    13. Check the mains supply voltage and insure there isn't ant sudden change in voltage.
    14. Send the inverter for repair.
    15. Check whether the input voltage is normal
    16. check whether there is a sudden change in load.
    17. Check whether there is any phase missing.
    18. Check the fan in the inverter. Is it spinning? Is it blocked? Does it have any foreign matter stuck on the fins of the fan? If so, clear the fan.
    19. Check the ambient temperature in the space that the inverter is placed.
    20. Check for adequate ventilation for the inverter where it is placed.
    21. Check for jamming or any sudden change with respect to mechanical load.
    22. Set the V/F curve correctly.
    23. The motor is too small.
    24. The motor is hot and the insulation of the motor degraded.
    25. Check if the voltage has a large variance.
    26. Check if there is a phase missing.
    27. Contact the supplier

    Additional Information:
    I have cnc wood carving machine 1325 the inverter showing error 0006

    Click the link to respond:
    what does it mean when my spindle VFD inverter shows OC-2?

  • What is the benefit to using a spindle over a standard router?

    This solution will refer to the water cooled spindles that we sell. Generally, routers are air cooled which push air downwards through the router to cool the router motor. This has an undesirable effect for CNC machines that will blow the dust and chips into the air. The water cooled spindle will not blow since it uses water to cool the spindle motor. This allows the chips and dust to be confined within the dust shoe and get removed by the vacuum. Additionally, standard routers have a sound level that far exceeds that of the spindle.

    Click the link to respond:
    What is the benefit to using a spindle over a standard router?

  • WHAT ELECTRICAL CABLE DO I USE TO CONNECT VFD INVERTER SPINDLE?

    The type of wire that should be used between the spindle and the VFD (Variable Frequency Driver also called the inverter) should be of stranded type and we use between 18 and 16 AWG.

    The total current is divided among the three coil wires, therefor a wire gauge of 16 should be sufficient.

    Currently we use 20AWG 4 conductor.

    Additional Information:

    Click the link to respond:
    WHAT ELECTRICAL CABLE DO I USE TO CONNECT VFD INVERTER SPINDLE?

  • What is the runout on the 2.5 KW spindle and how many bearings?

    The runout on our 2.2kW spindle and number of bearings are:
    Radial runout: 0.01mm - 0.000393701 inches, 3 Bearings

    Click the link to respond:
    What is the runout on the 2.5 KW spindle and how many bearings?