Question #: 13805

Question: Could I safely use a 2200w 220 to 110 converter and uninteruptable power supply with my 2.2kw inverter and spindle?

Current Solution

Yes, you can use a 220 to 110 step down transformer to provide power to your 2.2kw VFD and spindle.

Respond:

Other Possible Solutions to this Question

  • hi, would like to make a change on my order, i purchase this part 2.2kW Spindle with 220V Inverter $528.00, and would like to make it for 110 volts instead of 220v. please

    Sure, not a problem at all. You will need to call our office and provide your information so that we can change the correct order.

    Our phone number can be seen by hovering over the "Need Help?" at the top right of each page.

    Click the link to respond:
    hi, would like to make a change on my order, i purchase this part 2.2kW Spindle with 220V Inverter $528.00, and would like to make it for 110 volts instead of 220v. please

  • I would like to know what the lowest rpm that can be acheived with the 2.2kw spindle and inverter and still have enough torque to drill

    According to the supplier of the 2.2 kW spindle, the safest operating speed for the spindle is 6000 RPM. The supplier also stated that theoretically, the spindle can operate from 0 to 24,000 RPM. I am continuing a dialog with the supplier to delve deeper into understanding the configurations and ramifications of such configurations for operations outside of the safe boundaries into the "theoretical" ranges.

    Additional Information:
    20

    Click the link to respond:
    I would like to know what the lowest rpm that can be acheived with the 2.2kw spindle and inverter and still have enough torque to drill

  • Transaction EQEPB4915043, My 2.2Kw Spindle and Inverter showed up without any manual or instructions. Can you provide a manual? Thank you

    The spindle does not come with a manual, however the inverter should come with a manual booklet in the box. The wiring diagram and PD settings for the inverter and spindle (https://www.buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-novfd) can be view together on the spindle page, also you can use a local hardware store extension cord (orange) to connect/wire from your outlet(220V) to your inverter and spindle accordingly from the diagram.

    Additional Information:
    I also received a spindle and inverter without a manual. While the diagrams on the product page were sufficient to get the unit running, there is no documentation anywhere to be found concerning the terminal block that is used for external control. What does one have to do to get a hold of the manual that was supposed to come with the inverter? Manuals for the 220VAC model are plentiful online; however, manuals for the 110VAC model are non-existent.

    Click the link to respond:
    Transaction EQEPB4915043, My 2.2Kw Spindle and Inverter showed up without any manual or instructions. Can you provide a manual? Thank you

  • Is 1000W voltage converter (110V to 220V) enough for 2.2kW spindle?

    Ideally, the spindle VFD should use an actual 220V socket that contains the minimum amp fuse that will allow the appropriate draw for all of the items that will be plugged into that socket. If you elect to use a boost converter, the 2.2kW spindle VFD will need a 2200 watts or more.

    My brother is using 1000W and told me his spindle is working just fine. Is it safe to use 1000W ?

    I still can't recommend using a 1000W converter.

    Click the link to respond:
    Is 1000W voltage converter (110V to 220V) enough for 2.2kW spindle?

  • 2.2kW Spindle with 110V Inverter, can I get a collet for 1/2 router bits for this spindle

    Absolutely. You can have 1/2" collets used in 2.2kW spindles.

    Here is a link for the ER-20 1/2"ID Collet:
    https://www.buildyourcnc.com/item/spindle-collet-!5-er20-spindle-collet

    Click the link to respond:
    2.2kW Spindle with 110V Inverter, can I get a collet for 1/2 router bits for this spindle

  • what is the warranty period and do you repair these in house? 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)

    Spindles are generally covered up to 1 year after date of purchase. We do not repair them in house, but we do work with our manufacturer to replace defective units. Generally if you have a defective unit covered under warranty, we will issue a replacement.

    Click the link to respond:
    what is the warranty period and do you repair these in house? 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)

  • I PURCHASED A VFD AND SPINDLE FROM FRIEND, HIS SET UP IS 220. DON'T HAVE 220 IN MY SHOP. QUESTION CAN USE YOUR 110 WITH THIS SPINDLE??

    Depending if the spindle can work with this specific VFD, it might be possible. However we would not like to risk you working unit, with a possible match so we would like more details on your specific model and any information available on the spindle itself.

    Response
    The only info on the spindle is 2.2KW 400HZ 220V. Made by Zhong Hua Jiang.

    Was originally on a Delta C200 vfd. That is 220 single phase.

    Click the link to respond:
    I PURCHASED A VFD AND SPINDLE FROM FRIEND, HIS SET UP IS 220. DON'T HAVE 220 IN MY SHOP. QUESTION CAN USE YOUR 110 WITH THIS SPINDLE??

  • I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to respond:
    I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

  • I purchased a vfd and spindle from a friend, his set up is 220. I don't have 220 in my shop. My question is can I use your 110 vfd with this spindle??

    Depending if the spindle can work with this specific VFD, it might be possible. However we would not like to risk you working unit, with a possible match so we would like more details on your specific model and any information available on the spindle itself.

    Response
    The only info on the spindle is 2.2KW 400HZ 220V. Made by Zhong Hua Jiang.

    Was originally on a Delta C200 vfd. That is 220 single phase.

    Click the link to respond:
    I purchased a vfd and spindle from a friend, his set up is 220. I don't have 220 in my shop. My question is can I use your 110 vfd with this spindle??

  • How to display RPM instead of frequency on the VFD? I have the 2.2kv 110 volt spindle and inverter.

    There is a button on the front of the VFD that will cycle through RPM, Freq, and a few other readings. If there is a >> button on your VFD, that will work. If there is a mode button on your VFD, that should works as well.

    Additional Information:
    There is a >> disc button but it does not cycle through the display modes.

    Additional Information:
    Is there a parameter setting to make this button work to cycle thru the display modes?

    Click the link to respond:
    How to display RPM instead of frequency on the VFD? I have the 2.2kv 110 volt spindle and inverter.

  • Is a 110v 20a circuit sufficient to run the spindle (2.2kw w/110v inverter)?

    t might be a better idea to increase the circuit breaker above 20 as 2200/110 is exactly 20. You will not have a buffer there in case you need it. Alternatively, you can decrease the current draw of the spindle in the VFD programming process.

    Click the link to respond:
    Is a 110v 20a circuit sufficient to run the spindle (2.2kw w/110v inverter)?

  • I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to respond:
    I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

  • I ordered a 1.5kW Spindle and Inverter (110 Volt) on December 18th and have heard nothing since. I notice you did charge my credit card for the purchase. Please update me with an ETA as soon as possible.

    I just looked at your account and noticed that your shipments has not been made yet. I will talk to the shipper tomorrow morning when the office opens determine what happened. My apologies for this.

    Click the link to respond:
    I ordered a 1.5kW Spindle and Inverter (110 Volt) on December 18th and have heard nothing since. I notice you did charge my credit card for the purchase. Please update me with an ETA as soon as possible.

  • I have a YDH-18-5 Power Supply AC Input:100-240v 47-63Hz, Ouput: 5v - 2A and need to know if its safe to use with the Parallel Breakout Board.

    The 5V power required for the breakout board can be a simple USB male to male cable, that will connect from your computer to the board itself.
    Now adding a external power supply make sure that it does not exceed a total of 5V and the standard 500 MilliAMP - 1 A.

    Click the link to respond:
    I have a YDH-18-5 Power Supply AC Input:100-240v 47-63Hz, Ouput: 5v - 2A and need to know if its safe to use with the Parallel Breakout Board.

  • It is possible to control externally the 1.5kW Inverter (VFD) (220 Volt) with PWM so i can control the spindle rotation? Do you have the documentation? Thank you

    Our spindle VFD's, have a multitude of different connectors that can be used for different operations. There is a manual that comes with each VFD, and you can refer to page 11 for different functions and descriptions.

    We currently have a PWM, working with our machine, however it is connected via USB, and setup through Mach 3.
    Also if you may have misplaced or lost the manual here is a link to the pdf:

    (https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&uact=8&ved=0CCAQFjAAahUKEwibxaaIndTHAhXQlogKHZVyDFE&url=http%3A%2F%2Fwww.c-n-c.cz%2Fdownload%2Ffile.php%3Fid%3D42252&ei=_cHkVdvSC9CtogSV5bGIBQ&usg=AFQjCNHTQcxs-KhJkvkhMdxVFPzkoYJtsA&sig2=JAcZawTGMuC-t4wmn1z-rA)

    Click the link to respond:
    It is possible to control externally the 1.5kW Inverter (VFD) (220 Volt) with PWM so i can control the spindle rotation? Do you have the documentation? Thank you

  • What power supply do you recommend for the spindle and limit switches if I buy the USB Mach3 breakout board?

    Any of the following power supplies will be fine for powering the Mach3 USB controller:
    https://www.buildyourcnc.com/item/24v

    however, the limit switches do not need high current, so the following power supply is sufficient for the task of connecting limit switches:
    https://www.buildyourcnc.com/item/electronicsAndMotors-power-supply-24v-1a-dc

    Click the link to respond:
    What power supply do you recommend for the spindle and limit switches if I buy the USB Mach3 breakout board?

  • What all is included in the GreenLean kit (sold with RedSprout and spindle/inverter)?

    The greenLean with the redSprout and the spindle option has everything you need excluding the spoilboard and the end mill.

    Click the link to respond:
    What all is included in the GreenLean kit (sold with RedSprout and spindle/inverter)?

  • Good morning, I would like to know if the strength of the 2.2kw spindle is weaker when using the 110V version of the VFD. Does it have the same power as the 220V version VFD?

    The 2.2kW spindle will have the same amount of torque and strength using either the 110V or the 220V inverter. Nothing will significantly change in either application since the 110V inverter has a small step up transformer which will increase the voltage from 110V to 220V to run the spindle efficiently.

    Additional Information:
    I'd like confirmation on this -- isn't there a cost in efficiency to having the 110v step up to 220v?

    Click the link to respond:
    Good morning, I would like to know if the strength of the 2.2kw spindle is weaker when using the 110V version of the VFD. Does it have the same power as the 220V version VFD?

  • 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD) Geven Me My contuy Bangladesh

    Spindles are generally covered up to 1 year after date of purchase. We do not repair them in house, but we do work with our manufacturer to replace defective units. Generally if you have a defective unit covered under warranty, we will issue a replacement.

    Click the link to respond:
    2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD) Geven Me My contuy Bangladesh