Question: I would like to know what the lowest rpm that can be acheived with the 2.2kw spindle and inverter and still have enough torque to drill

Current Solution

According to the supplier of the 2.2 kW spindle, the safest operating speed for the spindle is 6000 RPM. The supplier also stated that theoretically, the spindle can operate from 0 to 24,000 RPM. I am continuing a dialog with the supplier to delve deeper into understanding the configurations and ramifications of such configurations for operations outside of the safe boundaries into the "theoretical" ranges.

Additional Information:
20

Respond:

Other Possible Solutions to this Question

  • Hi, I'm interested in the 1.5 kW (kilowatt) Water Cooled Spindle with Inverter (VFD), I would like to know about the run out of this spindle?

    Our spindles have a runout of less than .0001 in, which includes that collets that we sell. If you use a collet from another manufacturer, we cannot guarantee this TIR (Total Indicated Runout) dimension.

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    Hi, I'm interested in the 1.5 kW (kilowatt) Water Cooled Spindle with Inverter (VFD), I would like to know about the run out of this spindle?

  • I have the 2.2KW VFD. I would like to have it controlled through software. What are the Mode parameters that need to be changed that will allow FWD/ REV, START/STOP and RPM control?

    What controller are you using to control the cnc machine (Mach3 usb, parallel breakout board, etc.)?

    The spindle VFD has an input for 0-10 volts to control the speed and can be used with the MAch3 USB or the Pokeys57CNC board. There are also other terminals in the VFD to control the forwared/reverse and start and stop. Mach3 has parameters to control these output and you need to specify which pins are used for these.

    You can also use the TX/RX RS-485 connection on the VFD to have total control using an FTDI USB to serial connector board to connect the computer directly to the VFD.

    How to connect the USB to Serial adapter to the VFD:
    https://www.buildyourcnc.com/FAQ/13790

    FTDI USB to Serial:
    https://www.buildyourcnc.com/item/Interfaces-newbiehack-Interfaces-TTL232R-USB-UART-Serial

    Pokeys57CNC board:
    https://www.buildyourcnc.com/item/electronicsAndMotors-electronic-component-breakout-Mach4-mach3-USB-ethernet-Board

    Mach3 USB board:
    https://www.buildyourcnc.com/item/electronicsAndMotors-electronic-component-breakout-Mach3-USB-Board

    Parallel Breakout board:
    https://www.buildyourcnc.com/item/electronicsAndMotors-parallel-breakout-relay



    Additional Information:
    I do apologize for leaving out the parts list.
    Leadshine MX4660 4-Axis Digital Stepper Motor Driver
    Ethernet SmoothStepper
    YL600-2S-2K20 VFD
    4 Relay control board
    Has anyone had any success getting Mach3 to control the spindle speed and direction?

    Click the link to add information to this solution:
    I have the 2.2KW VFD. I would like to have it controlled through software. What are the Mode parameters that need to be changed that will allow FWD/ REV, START/STOP and RPM control?

  • hi, would like to make a change on my order, i purchase this part 2.2kW Spindle with 220V Inverter $528.00, and would like to make it for 110 volts instead of 220v. please

    Sure, not a problem at all. You will need to call our office and provide your information so that we can change the correct order.

    Our phone number can be seen by hovering over the "Need Help?" at the top right of each page.

    Click the link to add information to this solution:
    hi, would like to make a change on my order, i purchase this part 2.2kW Spindle with 220V Inverter $528.00, and would like to make it for 110 volts instead of 220v. please

  • Good morning, I would like to know if the strength of the 2.2kw spindle is weaker when using the 110V version of the VFD. Does it have the same power as the 220V version VFD?

    The 2.2kW spindle will have the same amount of torque and strength using either the 110V or the 220V inverter. Nothing will significantly change in either application since the 110V inverter has a small step up transformer which will increase the voltage from 110V to 220V to run the spindle efficiently.

    Additional Information:
    I'd like confirmation on this -- isn't there a cost in efficiency to having the 110v step up to 220v?

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Click the link to add information to this solution:
    Good morning, I would like to know if the strength of the 2.2kw spindle is weaker when using the 110V version of the VFD. Does it have the same power as the 220V version VFD?

  • I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to add information to this solution:
    I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

  • It is possible to control externally the 1.5kW Inverter (VFD) (220 Volt) with PWM so i can control the spindle rotation? Do you have the documentation? Thank you

    Our spindle VFD's, have a multitude of different connectors that can be used for different operations. There is a manual that comes with each VFD, and you can refer to page 11 for different functions and descriptions.

    We currently have a PWM, working with our machine, however it is connected via USB, and setup through Mach 3.
    Also if you may have misplaced or lost the manual here is a link to the pdf:

    (https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&uact=8&ved=0CCAQFjAAahUKEwibxaaIndTHAhXQlogKHZVyDFE&url=http%3A%2F%2Fwww.c-n-c.cz%2Fdownload%2Ffile.php%3Fid%3D42252&ei=_cHkVdvSC9CtogSV5bGIBQ&usg=AFQjCNHTQcxs-KhJkvkhMdxVFPzkoYJtsA&sig2=JAcZawTGMuC-t4wmn1z-rA)

    Click the link to add information to this solution:
    It is possible to control externally the 1.5kW Inverter (VFD) (220 Volt) with PWM so i can control the spindle rotation? Do you have the documentation? Thank you

  • [575] Hi, I plug HY 220v spindle on the board. It work, but the is a unstable frequency on the spindle. I put shielded wires from BOB to Inverter, and from Inverter to Spindle. But the problem still there. I read that I have to put a Analogue PWM, is that true, or I have problem with my wires... Thank you

    You may want to try using a ferrite core or an inductor in addition to the shielded cable. Also, make sure you are grounding the shield at both ends. Even though this is not high frequency, grounding the shield at both ends in a motor scenario may help. Also, try to reduce any parallel wire runs.

    Click the link to add information to this solution:
    [575] Hi, I plug HY 220v spindle on the board. It work, but the is a unstable frequency on the spindle. I put shielded wires from BOB to Inverter, and from Inverter to Spindle. But the problem still there. I read that I have to put a Analogue PWM, is that true, or I have problem with my wires... Thank you

  • How to display RPM instead of frequency on the VFD? I have the 2.2kv 110 volt spindle and inverter.

    There is a button on the front of the VFD that will cycle through RPM, Freq, and a few other readings. If there is a >> button on your VFD, that will work. If there is a mode button on your VFD, that should works as well.

    Additional Information:
    There is a >> disc button but it does not cycle through the display modes.

    Additional Information:
    Is there a parameter setting to make this button work to cycle thru the display modes?

    Additional Information:
    setting the starting rpm

    Additional Information:
    the vfd will not start the motor

    Additional Information:
    Any progress on this? I have the same issue.

    Additional Information:
    What model is your VFD?

    Additional Information:
    Mine is a YL620-G-5.5Kw

    Additional Information:
    That model will not be able to show RPM. You will be able to show the frequency, which can be used to determine the RPM. RPM equals the Frequency x 60.

    Additional Information:
    There is an Icon for RPM at the top of the display I cannot cycle through the different options to see the RPM

    Additional Information:
    At the top of my control panel is has 6 different lights which indicate what your seeing. in order from left to right they are COM, ALM, DISP, RUN, Hz, RPM I have seen the ALM light up on initial set up but that was fixes with a parameter change. The run light shows up when i turn the spindle on and and it is running. I am however not able to get any of the other lights to show or to get the RPMs to display

    Additional Information:
    If you do see an RPM light on the display, that panel sticker may be a sticker used for many types of VFDs and the RPM is not used. There is parameter: P00.24 which allows you to pick what to display. The choices a
    re:
    0: Display current target frequency. This will display your knobs, potentiometer, setting, not the actual spindle frequency.
    1: Display electric machinery run frequency. This will display the actual frequency that the VFD is currently sending to the spindle.
    2: Display electric machinery run current: this will display the current the spindle is currently drawing.
    3: Display input AC voltage. Self explanatory.
    4: Display mother line voltage. This will display the actual voltage at the input.
    5: Display output voltage. This will display the voltage at the UVW terminals for the spindle.
    6: Display speed paragraph number SPx. I believe this displays which frequency is being selected (P07.00 to P07.07, or 1 to 8 respectively).
    7: Display inverter temperature. This is the temp of the VFD, self explanatory.
    8: Display input signal X1-X3/output signal. This simply shows the inputs/outputs associated with the external terminals.
    9: Display user variable. This one I have not delved into, so it may be something to look into.
    10: Display user count value. Same, this one could be useful.
    11: Display temporary debugging variable. Haven't tried this one, so I can't inform of any useful information but it won't pertain to this subject anyway.
    12: Display automatic multisegment run step and time. I haven't delved into this one either, but it won't show RPM.

    Click the link to add information to this solution:
    How to display RPM instead of frequency on the VFD? I have the 2.2kv 110 volt spindle and inverter.

  • I have a GMT 2.2kw water cooled spindle that sounds like the bearings are going out and want to know if your spindle (https://buildyourcnc.com/Item/spindle-inverter-2!2kw-spindle-novfd) is comparable for a swap. The drive is a Delta VFD-M 220v.

    Our spindle should work fine with your Delta VFD-M 220v. Spindles that match a VFD are specific to the coil windings. The bearings, shaft and other mechanical components that make up the spindle may be different, but that should not matter.

    Click the link to add information to this solution:
    I have a GMT 2.2kw water cooled spindle that sounds like the bearings are going out and want to know if your spindle (https://buildyourcnc.com/Item/spindle-inverter-2!2kw-spindle-novfd) is comparable for a swap. The drive is a Delta VFD-M 220v.

  • what is the warranty period and do you repair these in house? 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)

    Spindles are generally covered up to 1 year after date of purchase. We do not repair them in house, but we do work with our manufacturer to replace defective units. Generally if you have a defective unit covered under warranty, we will issue a replacement.

    Click the link to add information to this solution:
    what is the warranty period and do you repair these in house? 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)

  • [596] I am new to CNCs, curious to know what I need to look for in a pendant that would be compatible with this board and Mach4?

    I recommend using a wireless pendant rather than one that is wired to the controller.

    Here is a link to one on Amazon.com: https://amzn.to/3r3AfTm

    This is an affiliate link.

    Click the link to add information to this solution:
    [596] I am new to CNCs, curious to know what I need to look for in a pendant that would be compatible with this board and Mach4?

  • Could I safely use a 2200w 220 to 110 converter and uninteruptable power supply with my 2.2kw inverter and spindle?

    Yes, you can use a 220 to 110 step down transformer to provide power to your 2.2kw VFD and spindle.

    Click the link to add information to this solution:
    Could I safely use a 2200w 220 to 110 converter and uninteruptable power supply with my 2.2kw inverter and spindle?

  • I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to add information to this solution:
    I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

  • I have purchased cable carrier chain and would like to know if you could send me a copy of that order as I need to purchase extra lengths of the links I bought. Thanks

    If you were logged in when you made the purchase, you can click the "My Account" link at the top of any page on this website and see all of your orders, order line items (with direct links to these items), and shipment information.

    Here is a link to the "My Account" page for your convenience:
    https://www.buildyourcnc.com/CustomerInfo.aspx

    I did not see your username on your internal customer record, so I added this username and you should be able to see the information in the "My Account" page.

    Additional Information:
    I just tested your accounts page and the cable carrier links are in there. Thanks and please let me know if you need further assistance.

    Click the link to add information to this solution:
    I have purchased cable carrier chain and would like to know if you could send me a copy of that order as I need to purchase extra lengths of the links I bought. Thanks

  • I have the same water for months to cool the spindel and it's blocked, what can I use to unblock it? I would not like to damage any seal or gasket inside.

    Usually this does happen, we tend to clean the water out roughly every month, however we use our machine 8hrs a day, 7 days a week non stop. So Depending on your usage it might be every 3-5 months when you might have to change the water.

    We use a small air compressor to blow the build up through the spindle.

    Click the link to add information to this solution:
    I have the same water for months to cool the spindel and it's blocked, what can I use to unblock it? I would not like to damage any seal or gasket inside.

  • i would like to turn on my water pump with out3 or 4 when i turn on the spindle. I have Mach3 working with the spindle on out1and 2. I have a relay wiredbut cant get out3 to flip.

    Take a look at these two videos that I created today on Instagram on the proper wiring of a relay to the Mach3 USB controller.

    https://www.instagram.com/tv/CMYGGBtj3cq/?utm_source=ig_web_copy_link
    https://www.instagram.com/tv/CMYLvq9DXVK/?utm_source=ig_web_copy_link

    Don't forget to watch the initial video on the Mach3 USB outputs on the Mach3 USB product page (last video on that page):
    https://www.buildyourcnc.com/item/electronicsAndMotors-electronic-component-breakout-Mach3-USB-Board

    Click the link to add information to this solution:
    i would like to turn on my water pump with out3 or 4 when i turn on the spindle. I have Mach3 working with the spindle on out1and 2. I have a relay wiredbut cant get out3 to flip.

  • HEY ! I HAVE PURCHASED A VFD WITH MATCHING SPINDLE 1.5KW AND CONTROL PROGRAM UCCNC. MY INTERFACE CARD IS DB25, THE QUESTION HOW DO CONNECT TO DB25 SO THAT CAN SPEED UCCNC? SINCERELY "CNC BEGINNERS"

    Identify the Control Signals: First, determine which control signals from the DB25 interface card are used for spindle speed control. Typically, these are PWM (Pulse Width Modulation) signals or analog voltage signals.

    VFD Configuration: Your VFD should be configured to accept the type of control signal your DB25 card provides. This involves setting parameters in the VFD that correspond to the type of input signal it will receive for speed control.

    Wiring: Connect the appropriate output pins from the DB25 card to the input terminals on the VFD. This usually involves connecting the PWM or analog output to the corresponding input on the VFD. Make sure to consult the manuals for both your VFD and interface card for specific wiring details.

    UCCNC Settings: Configure UCCNC to output the correct type of signal (PWM or analog) that matches your VFD's configuration. This is done through the software's spindle setup section.

    Test and Adjust: Run some tests to ensure that the spindle speed is being correctly controlled by UCCNC. You might need to tweak settings in either the VFD or UCCNC for optimal performance.

    Click the link to add information to this solution:
    HEY ! I HAVE PURCHASED A VFD WITH MATCHING SPINDLE 1.5KW AND CONTROL PROGRAM UCCNC. MY INTERFACE CARD IS DB25, THE QUESTION HOW DO CONNECT TO DB25 SO THAT CAN SPEED UCCNC? SINCERELY "CNC BEGINNERS"

  • If I am cutting 18mm MDF with 6mm cutting bit (so 6mm pass), what can be the maximum speed rate of cutting and spindle speed of router?

    The best way to determine the cutting speed is to determine this with respect to the edge quality you desire. This recommendation generally comes from the major end mill manufacturers.

    The feedrate (travel speed) should be determined by the chip load of the end mill, the number of flutes, material of the end mill (Solid Carbide, HSS - High Speed Steel, Cobalt, etc.) and the RPM of the spindle. You will need to see the manufacturer's specifications of the end mill to determine this information.

    Formula:
    Chip Load = (feed rate IPM)/(Spindle RPM x Number of Flutes)

    or

    Feed Rate IPM = Chip Load x Spindle RPM x Number of Flutes

    Once you find this information, apply this to the material at the full depth of the end mill. If you find that your edge condition is aberrant, pull back on either the speed, or the depth per pass. If the edge condition is acceptable, then push the speed higher until the edge condition starts to deteriorate in quality and then pull back to the accepted level.

    Using this method, you will be able to reduce the wear on the end mil which will be the most expensive consumable on the machine.

    Additional Information:

    Click the link to add information to this solution:
    If I am cutting 18mm MDF with 6mm cutting bit (so 6mm pass), what can be the maximum speed rate of cutting and spindle speed of router?

  • I have a 4x8 CNC and would like to cut my own parts for the Blackfoot. What is the price for the plans and the electronics ?

    The available options for the blackFoot, is only structural components with hardware, and structure components/hardware with electronic components.
    However we currently do not have any plans available for public use/distribution.

    Click the link to add information to this solution:
    I have a 4x8 CNC and would like to cut my own parts for the Blackfoot. What is the price for the plans and the electronics ?

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.