Question #: 3422

Question: I am missing the wiring information for the 1.5kw spindle, my electrician says I need documentation for the 4 prong connector into the VFD

Current Solution

You can find wiring diagrams and illustrations for the spindle on this page: https://buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-novfd

This information pertains to the 2.2 kW spindle; however, the wiring is the same for the other spindles as well.

Respond:

Other Possible Solutions to this Question

  • I need wiring diagram for motor to driver to usb motion card. I cannot find diagram. I have been unable to get information for a week.
  • I'm about to order your laser cutter , item 279 and a little confused.. in your faq it states you need wire and connectors for assembly, can you be specific on amount and guage of wire or tell me where to find that information?

    The connections between the driver and the breakout board(USB/Parallel)22-24 AWG wire is preference also going from the potentiometer going to LSPS(laser power supply) , now going from the power supply to the drivers/laser power supply 16-18 AWG wire is our preference.

    Click the link to respond:
    I'm about to order your laser cutter , item 279 and a little confused.. in your faq it states you need wire and connectors for assembly, can you be specific on amount and guage of wire or tell me where to find that information?

  • What are the model numbers for your 2.2kw 110v and 220v VFDs? Or can you share a link to their documentation?

    Documentation for Parameter setup is included with VFD purchase. For spindle wiring and programming, please refer to the product pages for the spindles or VFDs (or the combo kit) and scroll down to instructions. For further assistance you can contact customerservice@buildyourcnc.com

    Click the link to respond:
    What are the model numbers for your 2.2kw 110v and 220v VFDs? Or can you share a link to their documentation?

  • is everything included in the 4axis cnc kit to build a cnc control box like wires,connectors,wiring diagrams ect?

    The electronics combos come with stepping motor drivers, stepping motors, breakout board (interface between the computer and the drivers) and power supply. The electronic combos do not include the cable and wires since the mounting configuration can differ from application to application.

    The wiring diagrams are located on the product page for each product. For instance, to determine the wiring for the motors, go to the specific motor that you purchase and the datasheet will be available which will include the wiring configuration. The breakout board product page will contain the wiring diagram for the remaining electronics. You can also use the electronics videos found here (https://buildyourcnc.com/CNCElectronicsandWiring.aspx) to understand the best process to connect all of the electronics.

    Click the link to respond:
    is everything included in the 4axis cnc kit to build a cnc control box like wires,connectors,wiring diagrams ect?

  • It is possible to control externally the 1.5kW Inverter (VFD) (220 Volt) with PWM so i can control the spindle rotation? Do you have the documentation? Thank you

    Our spindle VFD's, have a multitude of different connectors that can be used for different operations. There is a manual that comes with each VFD, and you can refer to page 11 for different functions and descriptions.

    We currently have a PWM, working with our machine, however it is connected via USB, and setup through Mach 3.
    Also if you may have misplaced or lost the manual here is a link to the pdf:

    (https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&uact=8&ved=0CCAQFjAAahUKEwibxaaIndTHAhXQlogKHZVyDFE&url=http%3A%2F%2Fwww.c-n-c.cz%2Fdownload%2Ffile.php%3Fid%3D42252&ei=_cHkVdvSC9CtogSV5bGIBQ&usg=AFQjCNHTQcxs-KhJkvkhMdxVFPzkoYJtsA&sig2=JAcZawTGMuC-t4wmn1z-rA)

    Click the link to respond:
    It is possible to control externally the 1.5kW Inverter (VFD) (220 Volt) with PWM so i can control the spindle rotation? Do you have the documentation? Thank you

  • I'M SEARCHING FOR INFORMATION ABOUT THE HEALTH RISKS OF CELLULAR ANTENNAS' RADIATION. I NEED SCIENTIFIC (SCIENTIFIC PAPERS IN JOURNALS) THIS.

    Cellular telephone base stations are low-powered radiofrequency (RF) transmitters which operate at around 850-900 or 1800-1900 MHz (depending on the technology and region of the world). RF energy in a similar frequency range is used by many other technologies such as microwave ovens, UHF television, other communications systems, and radar. Health and safety issues related to RF energy have been studied for many years and there is an immense literature on the subject. Here are some sources that review health and safety issues related to RF energy from cellular base stations.

    A fact sheet published by the World Health Organization. There is also a Spanish version available on the WHO EMF website.
    Also see the IEEE EMBS Committee on Man and Radiation Report. Other reports are available through its website.
    The International Commission on Nonionizing Radiation Protection (ICNIRP) has published a lot on health and safety of RF energy. See its website. The ICNIRP published an article that describes the ICNIRP exposure limits for RF energy and their scientific rationale. See "Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields (up to 300 GHz)," Health Physics Vol. 74, No 4, pp 494-522, 1998.
    A very detailed assessment of the scientific evidence related to health and safety of mobile telephones and base stations is in the recent (May 2000) report by the Independent Expert Group on Mobile Phones (IEGMP) titled "Mobile Phones and Health" This study concludes "the balance of evidence to date suggests that exposures to RF radiation at levels below [international exposure guidelines] do not cause adverse health effects to the general population" but that "there may be biological effects at exposures below those guidelines." Public exposure to RF energy from cellular base stations is invariably far below the ICNIRP exposure guidelines.

    Kenneth R. Foster
    Professor, Bioengineering
    University of Pennsylvania

    Click the link to respond:
    I'M SEARCHING FOR INFORMATION ABOUT THE HEALTH RISKS OF CELLULAR ANTENNAS' RADIATION. I NEED SCIENTIFIC (SCIENTIFIC PAPERS IN JOURNALS) THIS.

  • I received a VFD 110v yl600-2s-2k20 p 110v with 220v instructions, also the connectors on the VFD dose not match any wiring configuration you have.

    Ok, I will check the YL600 documentation Monday 4/3 and provide the answer here.

    Additional Information:


    Additional Information:
    I also received one of these and the button labels do not even match your programming instructions as stated on your web set. Please provide updated instruction to match the model shipped with the correct button names to press in The programming process.

    Additional Information:
    7/15/17 - I have exact problem. I do not see the solution posted???

    Additional Information:
    Mine is a 2.2Kw YL-620 connected to a 1.5Kw spindle.

    Code Address Function Set Range &Function Explanation Factory Setting User Set Vendor Suggested As shipped Code Address Decimal
    P00.00 0 Main Frequency 0-120HZ(400HZ) 50.0HZ  400 60 399.6 P00.0 0
    P00.01 1 Start / stop command source 0: Operator board 0 0  0 P00.1 1
    1:From external end control Electric machinery,operation panel STOP key effective
    2:From external end son control Electric machinery,operation panel STOP key invalid
    3:from (Modbus Rs485) control Electric machinery
    4:By user application program control Electric machinery
    P00.02 2 Reserved   0   0 P00.2 2
    P00.03 3 Stopping Mode 0:Decelerating stop 0 0  1 P00.3 3
    1:Coasting stop 10
    2:DC brake stop 0.2
    P00.04 4 VF:Highest output frequency 1.0-120.0HZ(400HZ) 50.0HZ 400 60 400 P00.4 4
    P00.05 5 VF:Maximum Voltage Output Frequency 5.0-120.0HZ(400HZ) 50.0HZ 400 60 400 P00.5 5
    P00.06 6 VF:Highest output Voltage 10.0%-150.0% 100.00% 100.00% 100.00% 100 P00.6 6
    P00.07 7 VF:Middle Frequency 1.0-120.0HZ(400HZ) 3.0Hz 3.5Hz 3.0Hz 3.5 P00.7 7
    P00.08 8 VF:Middle Voltage 10.0%-100.0% 10% 20% 10% 10 P00.8 8
    P00.09 9 VF:Min Frequency 0-120.0HZ(400HZ) 0.2HZ 0.2Hz 0.2Hz 0.2 P00.9 9
    P00.10 10 VF:Min Voltage 0%-100.0% 5% 10.00% 5.00% 5 P00.10 10
    P00.11 11 Analog Input quantity 1 Regulation Multistage velocity 0%-100% 100 100 100 100 P00.11 11
    P00.12 12 VF :Curve Setting 0-4 0 0 P00.12 12
    P00.13 13 Parameter Lock 0: lnvalid 0 0 P00.13 13
    1: Valid
    10: Restore the factory setting No other function
    P00.14 14 Reserved 0 0 P00.14 14
    P00.15 15 Power on Time prohibit External end son Start-up 0:Power on time,allow External end input effective level,start-up Electric machinery 0 0 P00.15 15
    1:Power on time,Not allow
    P00.16 16 0: FWD(X5)yes,Positive run the 0 P00.16 16
    1: REV(X6) Determine direction : Open Yes
    2:X_EF=EF,X_REV(X5)_DIR=DIR,FWD(X6)=
    3: Stop ,FWD(X5) turn off Instantaneous
    4: FWD(X5) turn off Instantaneous
    5: FWD(X5) turn off Instantaneous
    6: Stop ,FWD(X5) turn off Instantaneous
    7: REV(X6)When open,FWD(X5)Start-up
    P00.17 17 Many function input X1 function Choice ####################################### ####################################### 1 1 P00.17 17
    P00.18 18 Many function input X2 function Choice 1.0HZ 1 P00.18 18
    P00.19 19 Many function input X3 function Choice 1 P00.19 19
    P00.20 20 Many function input X4 function Choice 1 P00.20 20
    P00.21 21 External Terminal rise/Slow down increment 0-120HZ(400HZ) 1.0HZ 1 P00.21 21
    P00.22 22 External Terminal rise/Slow down time interval 0.2 0.2 P00.22 22
    P00.23 23 Physics amount display Proportion constant 0-999.9% 100.00% 100 P00.23 23
    P00.24 24 After power supply, display project choice 0: Display current target frequency 0 0 P00.24 24
    1:Display Electric machinery run frequency.
    2:Display Electric machinery run current.
    3:Display input AC voltage
    4:Display mother Line voltage
    5:Display output voltage
    6:Display speed paragraph Number SP x
    7:Display inverter temperature t xx
    8:Display input signal X1-X3/output signal
    9:Display user variable
    10:Display user Count value
    11:Display temporary debugging variable
    12:Display automatic multi segment run step and time
    P00.25 25 Display project automatic Return delayed time (10/S) 0:No,Automatic return;1-6delayed 10-60S Back Return 1 1 P00.25 25
    P01.00 256 REV Rotation Select 0: Rev Run Enable 0 0 P01.0 256
    1: Rev Run Forbidden 0
    P01.01 257 Electric machinery Reversing wait for time 0 P01.1 257
    P01.02 258 Deceleration Prevention overvoltage setting(%) 130 130 P01.2 258
    P01.03 259 Accelerated Prevention overcurrent setting(%) 130 130 P01.3 259
    P01.04 260 Overcurrent Set up (%) 200 200 P01.4 260
    P01.05 261 Overload protection Set up (%) 130 130 P01.5 261
    P01.06 262 Overload protection time Set up (s) 120 120 P01.6 262
    P01.07 263 Undervoltage protection Set up (%) 80 80 P01.7 263
    P01.08 264 Overvoltage protection Set up (%) 150 150 P01.8 264
    P01.09 265 After shutdown, start DC Brake voltage Setup (%) 15 15 P01.9 265
    P01.10 266 After shutdown, End DC Brake voltage Setup (%) 0 0 P01.10 266
    P01.11 267 After shutdown, DC Braking Time Set up 2 2 P01.11 267
    P01.12 268 After shutdown, DC Braking Initial Frequency Set up 0.6 0.6 P01.12 268
    P01.13 269 Before start , input DC brake voltage set up (%) 20 20 P01.13 269
    P01.14 270 Before start , End DC Brake voltage Set up (%) 15 15 P01.14 270
    P01.15 271 Before start , DC Braking Time Set up 3 3 P01.15 271
    P01.16 272 Direct start Initial frequency (Improve starting torque ) 100 100 P01.16 272
    P01.17 273 Direct start Initial frequency Hold time 0 0 P01.17 273
    P01.18 274 power failure frequency decline 80 80 P01.18 274
    P01.19 275 The power down frequency decline rate 5 5 P01.19 275
    P01.20 276 Restart No load time 10 10 P01.20 276
    P01.21 277 Restart voltage rise time 200 200 P01.21 277
    P02.00 512 When speed up torque will increased   100  100 100 60 P02.0 512
    P02.01 513 Deceleration time - Torque Boost   100  100 100 60 P02.1 513
    P02.02 514 Accelerate curve Choice 0  0 P02.2 514
    P02.03 515 Deceleration curve Choice 0  0 P02.3 515
    P02.04 516 Avoid the f requency 1 20 400 P02.4 516
    P02.05 517 Avoid the f requency 2 30 30 P02.5 517
    P02.06 518 Avoid the f requency 3   40 40 P02.6 518
    P02.07 519 Avoid the f requency Width   0 0 P02.7 519
    P02.08 520 Window frequency 1 45 45 P02.8 520
    P02.09 521 Window frequency 2 50 50 P02.9 521
    P02.10 522 ? 400 P02.10 522
    P03.00 768 RS485 Communication Baud Rate 0: 1200Bps 5 4 P03.0 768
    1: 2400Bps
    2: 4800Bps
    3: 9600Bps
    4: 19200Bps
    5: 38400Bps
    6: 57600Bps
    P03.01 769 RS485 Communication Addresses 1-254 10 10 P03.1 769
    P03.02 770 0: 8 bit data, 1 stop bits, odd parity 2 2 P03.2 770
    1: 8 bit data, 1 stop bits, parity check
    2: 8 bit data, 1 stop bit, no parity
    3: 8 bit data, 2 stop bits, odd parity
    4: 8 bit data, 2 stop bits, parity check
    5: 8 bit data, 2 stop bit, no parity
    P03.03 771 Communication error handling 0 P03.3 771
    P03.04 772 Communication error tolerance time 20 P03.4 772
    P03.05 773 4-20mA Break detection time 0 P03.5 773
    P03.06 774 Panel potentiometer,Lower limit of AD norm 3 P03.6 774
    P03.07 775 Panel potentiometer,Upper limit of AD specification 1020 1015 1015 P03.7 775
    P03.08 776 Panel potentiometer, frequency given of lower limit 0.0HZ 0 0 P03.8 776
    P03.09 777 Panel potentiometer, frequency given of Upper limit 0-120HZ(400HZ) 60.0HZ 400  60Hz 400 P03.9 777
    P03.10 778 Analog lnput 1 AD lower limit 0-1023 3.0Hz  60Hz 3 P03.10 778
    P03.11 779 Analog lnput 1 AD Upper limit 0-1023 1020 1010 1010 P03.11 779
    P03.12 780 Analog lnput 1 frequency given lower limit 0.0HZ 0 P03.12 780
    P03.13 781 Analog lnput 1 frequency given Upper limit 60.0HZ 400 400 P03.13 781
    P03.14 782 Analog lnput 2 AD lower limit 3.0Hz 3 P03.14 782
    P03.15 783 Analog lnput 2 AD Upper limit 1020 1010 1010 P03.15 783
    P03.16 784 Analog lnput 2 frequency given lower limit 0.0HZ 0 P03.16 784
    P03.17 785 Analog lnput 2 frequency given Upper limit 60.0HZ 60 P03.17 785
    P03.18 786 Analog output correlation 0 0 P03.18 786


    P03.19 787 Analog output gain setting 100 100 P03.19 787
    P04.00 1024 Mo analog multiplier output frequency multiplier 10 10 P04.0 1024
    P04.01 1025 Mo1 Function Options 0 0 P04.1 1025
    P04.02 1026 Mo2 Function Options 1 1 P04.2 1026
    P04.03 1027 Multi-function Relay 1 Function selection 0:fault Yes Electric , otherwise power failure 0 2 2 2 P04.3 1027
    P04.04 1028 Multi-function Relay 2 Function selection 1:Running Yes Electric ,otherwise power failure 3 3.0Hz 3 P04.4 1028
    2: Reserved
    3: Arbitrary frequency arrival Time, have Electric,Related to P02-10 settings
    4: , The power down Time,have Electric
    5:, low voltage Time, have Electric
    6:, Overvoltage Time, have Electric
    7: Overcurrent Time, have Electric
    8: Nonzero velocity Time,have Electric
    9:, DC brake Time, have Electric
    10: Over torque Time, have Electric
    11: External interrupt fault Time, have
    12: Forward Time, have Electric
    13: Reversal Time, have Electric
    14: Move Time, have Electric
    15: Accelerate Time, have Electric
    16: Deceleration Time, have Electric
    17: Constant speed Time, have Electric
    18:X1 close Time, have Electric
    19:X2 close Time, have Electric
    20:X3 close Time, have Electric
    21:X4 close Time, have Electric
    22:X5 close Time, have Electric
    23:X6 close Time, have Electric
    24: Forward and bus voltage greater than 400V Time, have Electric
    25: Reverse and bus voltage greater than 400V Time, have Electric
    P04.05 1029 Multi-function Relay 1 Action close Delayed 0-65.5 S 0 0 P04.5 1029
    P04.06 1030 Multi-function Relay 1 disconnect delay action 0-65.5 S 0 0 P04.6 1030
    P04.07 1031 Multi-function Relay 1 Action close Delayed 0-65.5 S 0 0 P04.7 1031
    P04.08 1032 Multi-function Relay 1 disconnect delay action 0-65.5 S 0 0 P04.8 1032
    P04.09 1033 Stall rotor detection time 0-65.5 S 1 1 P04.9 1033
    P04.10 1034 Switch amount (Di) sampling time 0-1000mS 8 24 24 P04.10 1034
    P04.11 1035 Stopping Mode 0:Decelerating stop 0 0 P04.11 1035
    1:Coasting stop
    P05.00 1280 PID Output Upper limit frequency 50 50 P05.0 1280
    P05.01 1281 PID Output lower limit frequency 25 25 P05.1 1281
    P05.02 1282 PID Given Source 0 0 P05.2 1282
    P05.03 1283 PID Values Given 0.2 0.2 P05.3 1283
    P05.04 1284 PID Output characteristic(FOR /REV) 0 0 P05.4 1284
    P05.05 1285 PID Output characteristic (FOR/REV) 0 0 P05.5 1285
    P05.06 1286 PID Proportional Gain 0-100.0 50 50 P05.6 1286
    P05.07 1287 PID Integration Time Ti 0-100.0 0-100.0 50 50 P05.7 1287
    P05.08 1288 PID Derivative Time Td 0-100.0 0-100.0 50 50 P05.8 1288
    P05.09 1289 PID Deviation Limit 0-50.0 5 5 P05.9 1289
    P05.10 1290 PID Integral upper limit 50 50 P05.10 1290
    P05.11 1291 PID Given Change Time 0-600.0 1 1 P05.11 1291
    P05.12 1292 PID Feedback Filter Time 0 0 P05.12 1292
    P06.00 1536 Acceleration Time 0  0 P06.0 1536
    P06.01 1537 Accel.Time 1 0.1-6553.5 5.0 9  5.0 5 P06.1 1537
    P06.02 1538 Decel. Time 1 0.1-6553.5 5.0 8.6  5.0 5 P06.2 1538
    P06.03 1539 Accel.Time 2 0.1-6553.5 0.1-6553.5 2 2 P06.3 1539
    P06.04 1540 Decel. Time 2 0.1-6553.5 0.1-6553.5 2 2 P06.4 1540
    P06.05 1541 Accel.Time 3 0.1-6553.5 0.1-6553.5 2 2 P06.5 1541
    P06.06 1542 Decel. Time 3 0.1-6553.5 0.1-6553.5 2 2 P06.6 1542
    P06.07 1543 Accel.Time 4 0.1-6553.5 0.1-6553.5 2 2 P06.7 1543
    P06.08 1544 Decel. Time 4 0.1-6553.5 0.1-6553.5 2 2 P06.8 1544
    P06.09 1545 Accel.Time 5 0.1-6553.5 0.1-6553.5 2 2 P06.9 1545
    P06.10 1546 Decel. Time 5 0.1-6553.5 0.1-6553.5 2 2 P06.10 1546
    P06.11 1547 Accel.Time 6 0.1-6553.5 0.1-6553.5 2 2 P06.11 1547
    P06.12 1548 Decel. Time 6 0.1-6553.5 0.1-6553.5 2 2 P06.12 1548
    P06.13 1549 Accel.Time 7 0.1-6553.5 0.1-6553.5 2 2 P06.13 1549
    P06.14 1550 Decel. Time 7 0.1-6553.5 0.1-6553.5 2 2 P06.14 1550
    P06.15 1551 Accel.Time 8 0.1-6553.5 0.1-6553.5 2 2 P06.15 1551
    P06.16 1552 Decel. Time 8 0.1-6553.5 0.1-6553.5 2 2 P06.16 1552
    P06.17 1553 Jog Acceleration Time 0.1-6553.5 0.1-6553.5 2 2 P06.17 1553
    P06.18 1554 Jog Deceleration Time 0.1-6553.5 0.1-6553.5 2 2 P06.18 1554
    P07.00 1792 Frequency 1 0-120HZ(400HZ) 50HZ 50 50 P07.0 1792
    P07.01 1793 Frequency 2 50HZ 45 45 P07.1 1793
    P07.02 1794 Frequency 3 50HZ 40 40 P07.2 1794
    P07.03 1795 Frequency 4 50HZ 35 35 P07.3 1795
    P07.04 1796 Frequency 5 50HZ 30 30 P07.4 1796
    P07.05 1797 Frequency 6 50HZ 25 25 P07.5 1797
    P07.06 1798 Frequency 7 50HZ 20 20 P07.6 1798
    P07.07 1799 Frequency 8 50HZ 15 15 P07.7 1799
    P07.08 1800 Frequency source selection 1 0: Operator board (parameter: P03.06~P03.09) 0 0 P07.8 1800
    P07.09 1801 Frequency source selection 2 1: Pre-set Freq, P00.00 Set frequency value,Operation panel keyboard,Can be set directly 2 2 P07.9 1801
    P07.10 1802 Frequency source selection 3 2:No. X paragraph frequency P07.00~P07.07 2 2 P07.10 1802
    P07.11 1803 Frequency source selection 4 3: Analog Input. :P03.10~P03.13) 2 2 P07.11 1803
    P07.12 1804 Frequency source selection 5 4: external simulation amount 2 (VI2) 2 2 P07.12 1804
    P07.13 1805 Frequency source selection 6 5: (Modbus Rs485)Given frequency 2 2 P07.13 1805
    P07.14 1806 Frequency source selection 7 6: User application program, given frequency 2 2 P07.14 1806
    P07.15 1807 Frequency source selection 8 7:( Pid)Output frequency 2 2 P07.15 1807
    Other: Reserved
    Note:three control methods (P07.08) 1808 1.The motor speed is controlled by the operating panel P07.16 1808
    2.Motor speed control by external terminals (Potentiometer 10K). P00.01 set to 1, P07.08 set to 3
    3.Motor speed control by external terminals. P00.01 set to 1,P07.08 set to 1.
    P07.16 1809 Jogging Frequency FORWARD 0-120HZ(400HZ) 15.0HZ 15 P07.17 1809
    P07.17 2048 Jogging Frequency REV 0-120HZ(400HZ) 15.0HZ 13.0Hz 13 P08.0 2048
    P08.00 2049 Automatic many paragraph Running: Running direction Binary data format to set the direction of operation, see (the automatic multi segment operation, the operation of the direction set table) 0  0 P08.1 2049
    P08.01 2050 Automatic many paragraph Running: mode Choice 0:Automatic multi segment operation is invalid; 0 0 P08.2 2050
    1:After execution complete,Stop;
    2:After execution complete,Keep the last running state,Continued running;
    3:After execution complete, Repeated execution.
    P08.02 2051 Automatic many paragraph Running time Units:S/M 0:S;1:M 0 0 P08.3 2051
    P08.03 2052 Automatic many paragraph Running: No.1 paragraph Running time Automatic multi-section run time,Set up Section speed run time。Time units are determined by P08.02 Decision。Set run is 0,Indicates that this section is not executed. 10 1 1 P08.4 2052
    P08.04 2053 Automatic many paragraph Running: No.2 paragraph Running time 10 1.5 1.5 P08.5 2053
    P08.05 2054 Automatic many paragraph Running: No.3 paragraph Running time 10 1 1 P08.6 2054
    P08.06 2055 Automatic many paragraph Running: No.4 paragraph Running time 10 1.5 1.5 P08.7 2055
    P08.07 2056 Automatic many paragraph Running: No.5 paragraph Running time 10 1 1 P08.8 2056
    P08.08 2057 Automatic many paragraph Running: No.6 paragraph Running time 10 1.5 1.5 P08.9 2057
    P08.09 2058 Automatic many paragraph Running: No.7 paragraph Running time 10 1 1 P08.10 2058
    P08.10 2304 Automatic many paragraph Running: No.8 paragraph Running time 10 1.5 1.5 P09.0 2304
    P09.00 2305 frequency Range(%) 0-200% 0 0 P09.1 2305
    P09.01 2306 frequency wave Range(%) 0-400% 200 30 30 P09.2 2306
    P09.02 2307 frequency Rise time(S) 0.1-999.9 S 6.0 S 6 P09.3 2307
    P09.03 2560 frequency decline time(S) 0.1-999.9 S 5.0 S 5 P10.0 2560
    P10.00 2561 Counter reload,value 1000 1000 P10.1 2561
    P10.01 2562 Counter current value 0 0 P10.2 2562
    P10.02 2563 Timer reload,value 1000 1000 P10.3 2563
    P10.03 2816 Timer current value 0 0 P11.0 2816
    P11.00 2817 Output Status 1 1 P11.1 2817
    P11.01 2818 Output Voltage (V) 0 0 P11.2 2818
    P11.02 2819 Output Current (A) 5 5 P11.3 2819
    P11.03 2820 Output Frequency (Hz) 50 50 P11.4 2820
    P11.04 3072 Current Heatsink Temperature 25 25 P12.0 3072
    P12.00 3073 Rated Motor Current 5 5 P12.1 3073
    P12.01 3074 Rated Motor Voltage 220 220 P12.2 3074
    P12.02 3075 Motor Pole number 2-100 2 2 P12.3 3075
    P12.03 3076 Motor no-load current 10 10 P12.4 3076
    P12.04 3077 Motor no-load current detection time(S) 10 10 P12.5 3077
    P12.05 3078 Converter rated current(A) 5 5 P12.6 3078
    P12.06 3079 Converter rated Voltage(V) 220 220 P12.7 3079
    P12.07 3080 DC bus output voltage% 140 130 P12.8 3080
    P12.08 3081 Heat sink over temperature protection point 70 75 P12.9 3081
    P12.09 3082 Radiating fin temperature sensor configuration 1 1 P12.10 3082
    P12.10 3083 Abnormal reset implement wait time 120 120 P12.11 3083
    P12.11 3084 Fan Function Pattern 0:Motor running tine, start fan; 1 1 P12.12 3084
    1:When the fan operating temperature (P12.12) is exceeded,Instant start fan; When the temperature is lower than the fan temperature point,Delay about 1 minutes to close the fan;
    2:Unconditional forced start fan;
    3:Fan Inoperation;
    P12.12 3085 Cooling fan operating temperature 55 45 50 P12.13 3085
    P12.13 3086 Fan Testing 0 0 P12.14 3086
    P12.14 3087 Bypass relay closed detection 0 0 P12.15 3087
    P12.15 3088 Bypass Relay delay time 1.5 1 P12.16 3088
    P12.16 3089 Power on delay timer initial value(S) 50 50 P12.17 3089
    P12.17 3090 Electric current sensor To configure 1 1 P12.18 3090
    P12.18 3091 Automatic stable pressure function Choice 1 1 P12.19 3091
    P12.19 3092 PWM Frequency 2.0-15.0KHZ (110V13.0KHZ 220V11.0KHZ 380V6.0KHZ) 8.0KHZ 13.0KHz 13 P12.20 3092
    P12.20 3328 SVPWM Pattern 0:Three-phase asynchronous motor, 0 0 P13.0 3328
    1:Two-phase asynchronous motor (Single-phase motor, 90 degree phase difference,Starting capacitor)
    P13.00 3329 103 P13.1 3329
    P13.01 3330 600 P13.2 3330
    P13.02 3331 1 P13.3 3331
    P13.03 3332 16.24 P13.4 3332
    P13.04 3333 1 P13.5 3333
    P13.05 3584 0 P14.0 3584
    P14.00 3585 35 P14.1 3585
    P14.01 3586 0.2 P14.2 3586
    P14.02 3587 1 P14.3 3587
    P14.03 3588 0 P14.4 3588
    P14.04 3589 0 P14.5 3589
    P14.05 3590 100 P14.6 3590
    P14.06 3591 1900 P14.7 3591
    P14.07 3592 2000 P14.8 3592
    P14.08 3593 59999 P14.9 3593
    P14.09 3594 5 P14.10 3594
    P14.10 3595 20 P14.11 3595
    P14.11 3596 0 P14.12 3596
    P14.12 3597 0 P14.13 3597
    P14.13 3598 0 P14.14 3598
    P14.14 3599 0 P14.15 3599


    Additional Information:
    Sorry, that is a paste from a spread sheet, you may have to do some formatting or paste it into a spread sheet to see it better...

    Additional Information:
    I will definitely do that. Thank you so much for providing the information!!

    Additional Information:
    I also have this problem with a yl620. Is there a solution?

    Additional Information:
    Is there a wiring diagram for the 110v units. My came with a 220 volt booklet.

    Additional Information:
    my unit also came with instructions for a 220 unit. I need a 110 wiring diagram.

    Additional Information:
    These instructions are lame at best, a friend of mine ordered one of these to install on a knife grinder that I built for him, and I proceeded to setup the unit, upon connecting it to the motor, it runs the motor, but hunt's at the lower speeds, and the setting I am looking for just isn't in the list, there's some settings in the 14's that don't say what there for, can anyone help?

    Click the link to respond:
    I received a VFD 110v yl600-2s-2k20 p 110v with 220v instructions, also the connectors on the VFD dose not match any wiring configuration you have.

  • I am upgrading a CNC with 3 stepping motors, and its all I want to keep. What technical information do you need in order to receive a quotation from you with the new items I need to buy from you?

    Dealing with your CNC upgrade we will need a good detail on exactly what you plan on keeping and reusing, all technical information about the parts that you keep will make our recommendations more precise for your application.

    Please email customerservice@buildyourcnc.com for any quote related questions.

    Click the link to respond:
    I am upgrading a CNC with 3 stepping motors, and its all I want to keep. What technical information do you need in order to receive a quotation from you with the new items I need to buy from you?

  • I AM TAKING THE FINAL YEAR PROJECT IN BASE STATIONS AND AIR INTERFACE. WOULD LIKE TO HAVE SOME INFORMATION.

    The Federal Communications Commission (FCC) is the primary federal agency responsible for safety aspects of modern-day wireless telecommunications systems. The FCC's Internet address is shown below. Recently FCC published an excellent report, cited below, to assist citizens and local governments dealing with siting of telecommuncations towers. This report contains charts and figures describing the characteristics and performance of telecommunications antennas. The report also contains practical guidance on application of provisions of the Telecommunications Act of 1996, which is the governing legislation regarding safety and siting of wireless telelcommunications facilities. Web page: RF Safety Program Page. Report title: "A Local Government Official's Guide to Transmitting Antenna RF Emission Safety: Rules, Procedures, and Practical Guidance." The Local and State Government Advisory Committee (LSGAC) and the FCC have developed this guide to aid local governmental officials and citizens in understanding safety issues related to radiofrequency emissions from telecommunications towers. Gary Zeman, Sc.D., CHP Lawrence Berkeley National Laboratory

    Click the link to respond:
    I AM TAKING THE FINAL YEAR PROJECT IN BASE STATIONS AND AIR INTERFACE. WOULD LIKE TO HAVE SOME INFORMATION.

  • I have a blacktooth laser engraver. The Y Axis stepper motor needs to be replaced. Can you please provide me with the information I would need to replace this motor.

    Yes, if you need a replacement part on your machine please call us at 281-815-7701.

    Click the link to respond:
    I have a blacktooth laser engraver. The Y Axis stepper motor needs to be replaced. Can you please provide me with the information I would need to replace this motor.

  • I'm planning a rack and pinion style gantry, and need clarification on how to slave a second stepper to the Y (or X). Can you direct me to that information for your products?

    There are two things to consider when using two stepping motors on a single axis. Since you want both motors to spin at the same rate and possibly in the same direction, you need to connect both motor drivers to the same breakout board pins. For example, if you want two motors on the x-axis and the x-axis pins on the breakout board are #2 for step and #3 for direction, the #2 will connect to the step (cp) terminal on each driver and the #3 will connect to the dir (cw) terminal on each driver.

    However, if the motors will be opposing (one motor will need to spin in the other direction), you will need to consider either flipping the rack on one side, or adding a circuit to invert the direction (#3) signal going to that driver.

    Click the link to respond:
    I'm planning a rack and pinion style gantry, and need clarification on how to slave a second stepper to the Y (or X). Can you direct me to that information for your products?

  • I need to determine steps/inch mach3 setup information for my motors and drivers.

    blueChick:

    X-axis
    “CW230 (3.0A) Driver”
    Set to 1/16 Microstep, 2.7A
    Dipswitches: 11001100
    Mach3 Motor Tuning: 1422.22 steps/in

    Y-axis
    “CW230 (3.0A) Driver”
    Set to 1/16 Microstep, 2.7A
    Dipswitches: 11001100
    Mach3 Motor Tuning: 1422.22 steps/in

    Z-axis
    “CW230 (3.0A) Driver”
    Set to 1/4 Microstep, 2.7A
    Dipswitches: 10101100
    Mach3 Motor Tuning: 1600 steps/in

    blackToe:

    X-axis
    “CW230 (3.0A) Driver”
    Set to 1/16 Microstep, 2.7A
    Dipswitches: 11001100
    Mach3 Motor Tuning: 1422.22 steps/in

    Y-axis
    “CW230 (3.0A) Driver”
    Set to 1/16 Microstep, 2.7A
    Dipswitches: 11001100
    Mach3 Motor Tuning: 1422.22 steps/in

    Z-axis
    “CW230 (3.0A) Driver”
    Set to 1/4 Microstep, 2.7A
    Dipswitches: 10101100
    Mach3 Motor Tuning: 1600 steps/in

    blackFoot:

    X-axis
    “CW8060 (6.0A) Driver”
    Set to 1/16 Microstep, 2.7A
    Dipswitches: 11001100 (“0”=down, “1”=up)
    Mach3 Motor Tuning: 914.29 steps/in

    Y-axis
    “CW230 (3.0A) Driver”
    Set to 1/16 Microstep, 2.7A
    Dipswitches: 11001100
    Mach3 Motor Tuning: 1422.22 steps/in

    Z-axis
    “CW230 (3.0A) Driver”
    Set to 1/4 Microstep, 2.7A
    Dipswitches: 10101100
    Mach3 Motor Tuning: 1600 steps/in

    greenBull:

    X-axis
    “CW8060 (6.0A) Driver”
    Set to 5.43A, 1/16 Microstep
    Dipswitches: 01100110 (“0”=down, “1”=up)
    Mach3 Motor Tuning: 914.29 steps/in

    Y-axis
    “CW8060 (6.0A) Driver”
    Set to 5.43A, 1/16 Microstep
    Dipswitches: 01100110
    Mach3 Motor Tuning: 914.29 steps/in

    Z-axis
    “CW8060 (6.0A) Driver”
    Set to 5.43A, 1/4 Microstep
    Dipswitches: 01100100
    Mach3 Motor Tuning: 1600 steps/in


    Scratch-Build / Book-Build Kit:

    X-axis
    “CW230 (3.0A) Driver”
    Set to 1/4 Microstep, 2.7A
    Dipswitches: 10101100 (“0”=down, “1”=up)
    Mach3 Motor Tuning: 1600 steps/in

    Y-axis
    “CW230 (3.0A) Driver”
    Set to 1/4 Microstep, 2.7A
    Dipswitches: 10101100
    Mach3 Motor Tuning: 1600 steps/in

    Z-axis
    “CW230 (3.0A) Driver”
    Set to 1/4 Microstep, 2.7A
    Dipswitches: 10101100
    Mach3 Motor Tuning: 1600 steps/in

    Additional Information:


    Additional Information:
    Scratch built/book CNC with NEMA 34 motors and CW8060 microstep driver

    Additional Information:

    Click the link to respond:
    I need to determine steps/inch mach3 setup information for my motors and drivers.

  • The breakout board that I have says that on the input pins I have five volts, the plan calls for these pins are ground connectors, which. Is correct?

    If you have the breakout board from this site, then the input pins have gnd connectors next to them. If you have a breakout board purchased elsewhere, or one of our older breakout boards, you may need to use the 5V connectors as the return, but make sure that the jumpers are set correctly. If you don't get any action from these switches in your software, recheck the jumpers and connections, or use the GND terminals on the power supply.

    Click the link to respond:
    The breakout board that I have says that on the input pins I have five volts, the plan calls for these pins are ground connectors, which. Is correct?

  • I can't seem to find information on spindle control via the breakout board. Can someone point me in the right direction?

    We currently can only control the On/Off of the spindle via Mach 3 and through our Parallel Interface Board. We have the listed instructions on our Parallel Interface Board webpage, will be a easy job that will included 2 wires (18-24g wire will be fine) from your inverter(VFD) to the location of your Parallel Interface Board.

    Parallel Interface Board webpage: https://buildyourcnc.com/item/electronicsAndMotors-parallel-breakout-relay

    In regards to our USB Interface Board, we are currently working on a prototype board that will allow the same On/Off capability with Planet-CNC. Prototype Board currently not available as of yet.

    Click the link to respond:
    I can't seem to find information on spindle control via the breakout board. Can someone point me in the right direction?

  • please send wiring diagram for the 1500kw spindle and inverter combo. i need to see what additional things need be purchased. thanks.

    Please refer to the Spindle wiring diagram found on the product page for the 2.2KW spindle. The wiring diagram will be the same for the 1.5kW Spindle. The only difference will depend on if you are using 110v or 220v power, as setting PD008 asks you to specify the max voltage.

    Click the link to respond:
    please send wiring diagram for the 1500kw spindle and inverter combo. i need to see what additional things need be purchased. thanks.

  • got my stepper motors wired to the information on your website using USB Bob and the motors don't step they keep turning like an old drill until they stop

    So, if I understand correctly, the stepping motor will turn on command, but the motor will only turn in one direction. Check the output of your direction signal wire. Check the wire voltage when you command the motor to turn on one direction in the planet-cnc software. Then check the voltage when you command the motor to turn in the other direction. The voltage should be different in each case.

    Click the link to respond:
    got my stepper motors wired to the information on your website using USB Bob and the motors don't step they keep turning like an old drill until they stop

  • How can i calculate how much can carry my stepper motor? i have these informations: (Detent Torque: 2.2N.cm; Rotor Inertia: 54g.cm2; Holding Torque: 40N.cm). It's a nema 17

    The holding torque will provide the best information for the calculation on how much your stepper motor will carry. But first, when you say carry, do you mean how much weight it can lift, how much inertia it can withstand during an acceleration and deceleration state or how fast it can accelerate or velocity it can maintain under load from the milling process?

    Click the link to respond:
    How can i calculate how much can carry my stepper motor? i have these informations: (Detent Torque: 2.2N.cm; Rotor Inertia: 54g.cm2; Holding Torque: 40N.cm). It's a nema 17

  • How can i calculate how much can carry my stepper motor? i have these informations: (Detent Torque: 2.2N.cm; Rotor Inertia: 54g.cm2; Holding Torque: 40N.cm). It's a nema 17

    The holding torque will provide the best information for the calculation on how much your stepper motor will carry. But first, when you say carry, do you mean how much weight it can lift, how much inertia it can withstand during an acceleration and deceleration state or how fast it can accelerate or velocity it can maintain under load from the milling process?

    Click the link to respond:
    How can i calculate how much can carry my stepper motor? i have these informations: (Detent Torque: 2.2N.cm; Rotor Inertia: 54g.cm2; Holding Torque: 40N.cm). It's a nema 17

  • Should I have recieved documentation on any of the parts? No connection diagrams or pin callouts were included. No motor spec sheet either.

    All of the information and instructions for kits and products are shown on their respective product pages. If you need personal assistance, please give us a call and it will be our pleasure to guide you and solve any problem that you may have.

    Click the link to respond: