Question #: 3593

Question: Is 1000W voltage converter (110V to 220V) enough for 2.2kW spindle?

Current Solution

Ideally, the spindle VFD should use an actual 220V socket that contains the minimum amp fuse that will allow the appropriate draw for all of the items that will be plugged into that socket. If you elect to use a boost converter, the 2.2kW spindle VFD will need a 2200 watts or more.

My brother is using 1000W and told me his spindle is working just fine. Is it safe to use 1000W ?

I still can't recommend using a 1000W converter.

Respond:

Other Possible Solutions to this Question

  • How do you set up Frequency converter for 2.2kw spindle?

    Ideally, the spindle VFD should use an actual 220V socket that contains the minimum amp fuse that will allow the appropriate draw for all of the items that will be plugged into that socket. If you elect to use a boost converter, the 2.2kW spindle VFD will need a 2200 watts or more.

    My brother is using 1000W and told me his spindle is working just fine. Is it safe to use 1000W ?

    I still can't recommend using a 1000W converter.

    Click the link to respond:
    How do you set up Frequency converter for 2.2kw spindle?

  • Is there a video link showing connections to your most recent frequency converter for the 2.2 spindle (type:YL600-2S-2K20)? Cheers.

    I am currently making a video right now. I will post the video in a few days.

    Additional Information:
    You guys rock!

    Additional Information:
    Don’t judge us until you see the video!! Haha.

    Additional Information:
    Here is the video that I promised. The video covers the main wiring of the VFD and spindle.



    I will do another video on the parameters.

    Click the link to respond:
    Is there a video link showing connections to your most recent frequency converter for the 2.2 spindle (type:YL600-2S-2K20)? Cheers.

  • Could I safely use a 2200w 220 to 110 converter and uninteruptable power supply with my 2.2kw inverter and spindle?

    Yes, you can use a 220 to 110 step down transformer to provide power to your 2.2kw VFD and spindle.

    Click the link to respond:
    Could I safely use a 2200w 220 to 110 converter and uninteruptable power supply with my 2.2kw inverter and spindle?

  • Are there instructions to disassemble the 2.2KW spindle (220v)? We need to replace the bearings.

    We actually tried dissassembling one of our spindles in house with no success, but I just found a good thread on CNCZone that has a good set of photos and instructions.

    Here is the link: http://www.cnczone.com/forums/spindles-vfd/129454-water-cooled-chinese-spindle-disassembly.html

    Please let me know if this helps.

    Additional Information:
    Also, If you have no success, let us know and we will make an attempt here on video.

    Click the link to respond:
    Are there instructions to disassemble the 2.2KW spindle (220v)? We need to replace the bearings.

  • Your 2.2kw spindle w/inverter is out of stock for 110v, do you anticipate on offering these soon?

    We may deprecate these units as we had too many issues with them.

    Click the link to respond:
    Your 2.2kw spindle w/inverter is out of stock for 110v, do you anticipate on offering these soon?

  • In the 3 Axis Electronics Combo, what is the AC input of the power supply (110v or 220v??). is it possible to specify a certain voltage when ordering?

    In our 3-Axis electronics kit, the power supply's provided are capable of both 110V-220V. You have the capability to switch between both in case you might decide to run 220v in the near future or will relocate where 110v is being used.

    Additional Information:
    Connect spindle to the board

    Click the link to respond:
    In the 3 Axis Electronics Combo, what is the AC input of the power supply (110v or 220v??). is it possible to specify a certain voltage when ordering?

  • Is there a recommended break in process for a 2.2kw water cooled spindle?

    A break in process, I'm guessing means if the spindle needs to be turned off for some reason? If so, then no. The water cooled spindle can be run constantly. We run our spindle for very long periods of time.

    Click the link to respond:
    Is there a recommended break in process for a 2.2kw water cooled spindle?

  • What is a normal max operating temperature for a 2.2kw water cooled spindle?

    I don't know the exact temperature, but the spindle actually needs to get to a relatively high temperature for normal operation and to protect the bearings. IF I find better information from our supplier, I will add this information to this answer.

    Click the link to respond:
    What is a normal max operating temperature for a 2.2kw water cooled spindle?

  • I'm trying to get the planet-cnc mist, coolant and spindle output to work. It's showing no voltage when I test

    On the Planet-CNC board, the Mist, Spindle and Coolant outputs will require a relay to switch on those devices. Test one of those terminals with a multi-meter (Mist, Coolant, or Spindle). Each of these terminals have a GND next to the terminal for the device.

    Test the voltage across the GND to the terminal with the arrow that you want to test. Go to the software and click on the device you want to test (mist, coolant or spindle) and note the voltage. If no voltage is output then check under the board to where the terminals are soldered. Re-test the terminals across the solder joints rather than the terminal block wire inputs. If you get a voltage, then there is a problem with the terminal block. If you don't get a voltage, then the board is not functioning properly.

    Additional Information:
    I activated the output signal.. I did the tests indicated and I did not get voltage. I heated the welds of the three outputs and now works coolant but no mist or spindle, what should I do?

    Additional Information:
    There are probably cold joints on the board at the chip or the resistors on the traces for those terminals. You can send the board back to us and we will repair and test the board.

    Click the link to respond:
    I'm trying to get the planet-cnc mist, coolant and spindle output to work. It's showing no voltage when I test

  • What wire size between voltage converter and VFD?

    Please consult the advice of a professional electrician. The information provided below should always be confirmed by a professional electrician and you assume all risk involved when working with electricity which is potentially hazardous and lethal. Never work with instruments and wiring on live electricity.

    The wire gauge used between the spindle VFD and the wall socket, or voltage converter will be determined by the current consumption of the VFD. For example, if the spindle/vfd is rated for 2.2kW and the voltage input is 220V, then 2200W/220V = 10 amps. In this case, it's best to increase the gauge for a current flow to provide a safety factor and consider 15 amps rather than 10 amps. A wire gauge that is too small will cause overheating on the wire and possibly cause the insulation to melt and cause a short. A wire gauge of 14 (copper wire) for 15 amps would be adequate. Remember that the length of the wire is important. The longer the wire, the larger gauge is needed.

    It will be very short wires. Maybe 12" long.

    14 AWG should be fine.

    Click the link to respond:
    What wire size between voltage converter and VFD?

  • I would like to know what the lowest rpm that can be acheived with the 2.2kw spindle and inverter and still have enough torque to drill

    According to the supplier of the 2.2 kW spindle, the safest operating speed for the spindle is 6000 RPM. The supplier also stated that theoretically, the spindle can operate from 0 to 24,000 RPM. I am continuing a dialog with the supplier to delve deeper into understanding the configurations and ramifications of such configurations for operations outside of the safe boundaries into the "theoretical" ranges.

    Additional Information:
    20

    Click the link to respond:
    I would like to know what the lowest rpm that can be acheived with the 2.2kw spindle and inverter and still have enough torque to drill

  • What is the minimum RPM for the 2.2kW spindle?

    Spindles with 2 poles, which is typically for these types of spindles will have a minimum RPM of 6000 RPM or 100Hz; however, I would not run the spindle below 15000 RPM or 250Hz to give a safety factor and no damage will occur.

    If you have a 4 pole spindle, then much lower RPMs can be achieved, and with higher torque than a 2 pole spindle. The 4 pole spindle will require more power than 2 pole spindles and will not be able to achieve as high maximum RPMs.

    Click the link to respond:
    What is the minimum RPM for the 2.2kW spindle?

  • 2.2kW Spindle with 110V Inverter, can I get a collet for 1/2 router bits for this spindle

    Absolutely. You can have 1/2" collets used in 2.2kW spindles.

    Here is a link for the ER-20 1/2"ID Collet:
    https://www.buildyourcnc.com/item/spindle-collet-!5-er20-spindle-collet

    Click the link to respond:
    2.2kW Spindle with 110V Inverter, can I get a collet for 1/2 router bits for this spindle

  • Is a 110v 20a circuit sufficient to run the spindle (2.2kw w/110v inverter)?

    t might be a better idea to increase the circuit breaker above 20 as 2200/110 is exactly 20. You will not have a buffer there in case you need it. Alternatively, you can decrease the current draw of the spindle in the VFD programming process.

    Click the link to respond:
    Is a 110v 20a circuit sufficient to run the spindle (2.2kw w/110v inverter)?

  • Do you sell the cooling solution for the liquid cooled spindle 2.2kw.

    We are going to add a cooling solution very soon to the website. I am awaiting inventory of Fan and Radiators.

    The cooling units that we will be offering are the ones shown in the two pictures here:
    https://www.buildyourcnc.com/images/greenbullv2-2-800.JPG
    https://www.buildyourcnc.com/images/greenbullv2-4-800.JPG

    The fan/radiator is covered up a little bit in the first picture by the vacuum hose.

    Click the link to respond:
    Do you sell the cooling solution for the liquid cooled spindle 2.2kw.

  • how do you wire the 2.2kw spindle and vfd for 110 single phase

    You can find the wiring diagram for the 2.2kW spindle and, follow through instructions here.
    https://www.buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-novfd#prettyPhoto/8/

    Additional Information:


    Additional Information:
    wiring diagram at spindle top


    Additional Information:


    Additional Information:


    Additional Information:

    Click the link to respond:
    how do you wire the 2.2kw spindle and vfd for 110 single phase

  • Do I need Z axis mount for spindle? I currently have router cnc blacktoe

    You will need a Z-axis mount for Spindle if you are currently using a router.

    Click the link to respond:
    Do I need Z axis mount for spindle? I currently have router cnc blacktoe

  • Are there any other manuals for the VFD that comes with the 2.2kw spindle?

    We have manuals for the VFD rather than the spindles. Can you specify what issue you may be having so we can help you better?

    Additional Information:
    I am having trouble wiring the VFD. (From the wall outlet to the VFD) I think the manual or setup guide on your website is wrong. The two diagrams show two different sets of terminals on the page.

    Also, do you have a video or other documentation on programming the VFD? Your videos and documentation looks like it only covers the 1.2kw version. Are the two different spindles from different manufacturers?

    Click the link to respond:
    Are there any other manuals for the VFD that comes with the 2.2kw spindle?

  • I JUST RECEIVED A REPLACEMENT SPINDLE (2.2KW 220V). HOWEVER, WHEN ATTEMPTED IT USE THE NEW SPINDLE, WOULD ONLY REACH 1500 RPM. IS THERE SOMETHING NEED TO CHANGE ON CONTROLLER?

    VFD settings........
    1) To program the VFD, wire it up, plug it in. It takes several seconds to come to life.

    2) Push the PRGM button to enter programing mode.

    3 )Push the SET button. The display will read PD000.

    4) If you push the SET button again, it will display the present setting of PD000.

    5 )By pushing the up or down arrows, you can change the setting to whatever it needs to be. (This is just an example. PD000 needs no changes)

    6)Push the SET button again to lock in the setting of PD000 and advance to the next number, in this case, PD001.

    7) Push the SET button and it will display the present setting of PD001. Again, use the up and down arrows as necessary to set PD001, then push SET again to lock it in.

    Note: You can also scroll through the PD numbers with the up and down arrows.

    8) make all settings this way.

    9) by pushing the SET button you can scroll through the settings. First push of SET moves to the next number, second push displays it's setting, third push moves to the next PD number.

    Note- If you take too long, it will leave the programing mode on it's own. If it does, just push PRGM again to return to programing mode. Then press SET and continue what you were doing.

    10) Start with PD013. Set it to 1, which returns the settings to the factory settings.

    11) Then set PD005 to 400, PD004 to 400, and PD003 to 400 IN THAT ORDER.

    12) Then set the following: PD041=8, PD144=3000

    13) Set PD209=50

    That's it for the programing. You should get 24000RPM when you push RUN.

    Click the link to respond:
    I JUST RECEIVED A REPLACEMENT SPINDLE (2.2KW 220V). HOWEVER, WHEN ATTEMPTED IT USE THE NEW SPINDLE, WOULD ONLY REACH 1500 RPM. IS THERE SOMETHING NEED TO CHANGE ON CONTROLLER?