[ Log In ]
[ Register ]

Question #: 6887

Question: Interested in the 110v 1.5kw spindle and vfd. Need an er16, or preferably an er20 collett. Would this item work.

Current Solution

Currently in our current stock the collet that work with our 1.5kW spindle 110V/220V, will be the ER-11. Only the 2.2kW spindle uses the ER-20 collet.

Respond:

Other Possible Solutions to this Question

  • [77] Hello. I’m interested in buying a water cooled spindle and VFD. I have an Avid Pro CNC and would love to control it using Mach 4 but I keep hearing it’s difficult to integrate. Also, is the water pump 120 or 240? I’d love any advice etc. eBay is a web of confusion with all of the options. Thank you.

    You will need to look for the parameter that controls the run frequency. The frequency can be controlled bu the panel, external terminals, or the RS485 TX/RX terminals (UART protocol). You will want to change that parameter so it uses the panel. If you are referring to the maximum panel dial frequency is only allowing 200-300 rpm, then look for the parameters to control the frequency.

    For 200 RPM:
    Hz = 200/60 = 3.33 Hz

    For 300 RPM:
    Hz = 300/60 = 5 Hz

    Conversion to RPM:
    If you ever find yourself yearning to reverse-engineer the process, the formula is as follows:

    RPM = Hz × 60

    Look for values that match somewhere between 3 and 5 in your frequency parameters and replace them with 400 to give you 24,000 RPM max.

    Click the link to add information to this solution:
    [77] Hello. I’m interested in buying a water cooled spindle and VFD. I have an Avid Pro CNC and would love to control it using Mach 4 but I keep hearing it’s difficult to integrate. Also, is the water pump 120 or 240? I’d love any advice etc. eBay is a web of confusion with all of the options. Thank you.

  • I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to add information to this solution:
    I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

  • Hi i am interested in the greenBull 6x with Hybrid Laser/Spindle Head (includes Spindle/VFD and Laser Components) - USB Interface (Long Z). I was wondering how much it would cost to get this machine to NZ?

    You can use our shopping cart to determine the shipping. Add the machine and the parts you want to purchase, enter your shipping address and click on the Calculate Shipping Button to get a price for shipping. The shipping charges are determined directly from the carriers at the time of pressing that button.

    Additional Information:


    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    Hi i am interested in the greenBull 6x with Hybrid Laser/Spindle Head (includes Spindle/VFD and Laser Components) - USB Interface (Long Z). I was wondering how much it would cost to get this machine to NZ?

  • Can you provide setting for the VFD setting for 110v US, 1.5kw 220v spindle?

    The configuration settings for our VFD's are these: VFD Setup:
    Change PD001 to '0' (source of run commands)
    Change PD003 to 300 (main frequency - Hz)
    Change PD004 to 300 (base frequency - Hz)
    Change PD005 to 400 (max operating frequency - Hz)
    Change PD006 to 2.5 (intermediate frequency - Hz)
    Change PD008 to 220 (max voltage - V)
    Change PD009 to 15 (intermediate voltage - V)
    Change PD010 to 8 (minimum voltage - V)
    Change PD011 to 100 (frequency lower limit - Hz)
    Change PD142 to 7 (rated motor current - Amps)
    Change PD143 to 2 (motor pole number)
    Change PD144 to 3000 (rated motor revolution)
    For further info please refer to (https://www.buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-novfd#prettyPhoto) for wiring and other specifications.

    Click the link to add information to this solution:
    Can you provide setting for the VFD setting for 110v US, 1.5kw 220v spindle?

  • I have the 2.2 kW spindle and VFD for 110v, just wondering what amperage this draws, as my electricain buddy is telling me I need to put in a 20 amp breaker for this. I cant seem to find any amerpage draw on the INPUT label

    You can actually set a current limit in in the VFD using the programming process and the specifications in the manual that came with your VFD. You can expect the spindle at 220 Volts AC to draw (using the standard formula):

    For Volts, I will use 230 as the range is generally 220 to 240.

    Watts = Current * Volts

    Can also be written as:

    Current = Watts / Volts

    Current = 2.2kW (2200 watts) / 230 volts

    Current = 9.6 amps

    Click the link to add information to this solution:
    I have the 2.2 kW spindle and VFD for 110v, just wondering what amperage this draws, as my electricain buddy is telling me I need to put in a 20 amp breaker for this. I cant seem to find any amerpage draw on the INPUT label

  • I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to add information to this solution:
    I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

  • Can you provide configuration setting for the 110v Huangyang VFD and 1.5 kw spindle?

    The configuration settings for our VFD's are these: VFD Setup:
    Change PD001 to '0' (source of run commands)
    Change PD003 to 300 (main frequency - Hz)
    Change PD004 to 300 (base frequency - Hz)
    Change PD005 to 400 (max operating frequency - Hz)
    Change PD006 to 2.5 (intermediate frequency - Hz)
    Change PD008 to 220 (max voltage - V)
    Change PD009 to 15 (intermediate voltage - V)
    Change PD010 to 8 (minimum voltage - V)
    Change PD011 to 100 (frequency lower limit - Hz)
    Change PD142 to 7 (rated motor current - Amps)
    Change PD143 to 2 (motor pole number)
    Change PD144 to 3000 (rated motor revolution)
    For further info please refer to (https://www.buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-novfd#prettyPhoto) for wiring and other specifications.

    Click the link to add information to this solution:
    Can you provide configuration setting for the 110v Huangyang VFD and 1.5 kw spindle?

  • What are the configuration settings for VFD for Spindle 1.5kW 110V. The search settings have a link for a 2.2kw spindle so I'm afraid they are the wrong ones and I don't want to fry the spindle. My VFD is an Huanyang HY01D511B.

    Did you get a manual for your VFD? Where did you purchase the VFD and spindle?

    Additional Information:
    I bought the VFD through Amazon with a similar spindle that you sell. The VFD came with a manual but unfortunately the spindle had all the model number and specs scratched off of it. In an attempt to set it up, I fried the spindle. I have complained to the vendor and to Amazon but have received no solution. If your spindle arrives with proper documentation I probably can set it up myself.

    Click the link to add information to this solution:
    What are the configuration settings for VFD for Spindle 1.5kW 110V. The search settings have a link for a 2.2kw spindle so I'm afraid they are the wrong ones and I don't want to fry the spindle. My VFD is an Huanyang HY01D511B.

  • I have wired up my 110v VFD and my 2.2Kw spindle and I get an E.Lu.5 code. My wiring is correct and the parameters are set to those for the VFD according to your website I found in a previously answered question from someone here. Any help would be greatly appreciated, thank you!!

    The E.Lu.5 Error code on your VFD is related to Low Voltage.

    The recommended action is:
    - 1. Check whether the input voltage is normal. (the voltage from the wall/breaker to the VFD)
    - 2. Check whether there is a sudden change in load.
    - 3. Check whether there is any phase missing.

    Unfortunately, these three recommended actions will probable require an electrician to test the line going into the VFD.

    Additional Information:

    Click the link to add information to this solution:
    I have wired up my 110v VFD and my 2.2Kw spindle and I get an E.Lu.5 code. My wiring is correct and the parameters are set to those for the VFD according to your website I found in a previously answered question from someone here. Any help would be greatly appreciated, thank you!!

  • I ordered a 1.5kW 110V Spindle on 11/28. It still shows "processing." Is this on backorder? Any ETA I can expect?

    Yes, we were waiting for the VFDs and Spindles to arrive from China. We emailed you the tracking numbers today.

    Click the link to add information to this solution:
    I ordered a 1.5kW 110V Spindle on 11/28. It still shows "processing." Is this on backorder? Any ETA I can expect?

  • I WIRED MY VFD (2.2KW VERSION) AND TRIED TEST RUNNING THE SPINDLE. CONFIGURED TO YOUR SPECS ON THIS WEBSITE, ONLY ISSUE IS WE GOT AN ERROR CODE. ERR 02, DO YOU KNOW WHAT IS? OR HAVE A LIST OF CODES? THANK

    Can you provide the model number of your VFD?

    Yes, I have the "YL600 - 2S - 2K20"

    It just came with a small booklet that is all in Chinese...

    Click the link to add information to this solution:
    I WIRED MY VFD (2.2KW VERSION) AND TRIED TEST RUNNING THE SPINDLE. CONFIGURED TO YOUR SPECS ON THIS WEBSITE, ONLY ISSUE IS WE GOT AN ERROR CODE. ERR 02, DO YOU KNOW WHAT IS? OR HAVE A LIST OF CODES? THANK

  • Good morning, I would like to know if the strength of the 2.2kw spindle is weaker when using the 110V version of the VFD. Does it have the same power as the 220V version VFD?

    The 2.2kW spindle will have the same amount of torque and strength using either the 110V or the 220V inverter. Nothing will significantly change in either application since the 110V inverter has a small step up transformer which will increase the voltage from 110V to 220V to run the spindle efficiently.

    Additional Information:
    I'd like confirmation on this -- isn't there a cost in efficiency to having the 110v step up to 220v?

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Click the link to add information to this solution:
    Good morning, I would like to know if the strength of the 2.2kw spindle is weaker when using the 110V version of the VFD. Does it have the same power as the 220V version VFD?

  • I PURCHASED A VFD AND SPINDLE FROM FRIEND, HIS SET UP IS 220. DON'T HAVE 220 IN MY SHOP. QUESTION CAN USE YOUR 110 WITH THIS SPINDLE??

    Depending if the spindle can work with this specific VFD, it might be possible. However we would not like to risk you working unit, with a possible match so we would like more details on your specific model and any information available on the spindle itself.

    Response
    The only info on the spindle is 2.2KW 400HZ 220V. Made by Zhong Hua Jiang.

    Was originally on a Delta C200 vfd. That is 220 single phase.

    Click the link to add information to this solution:
    I PURCHASED A VFD AND SPINDLE FROM FRIEND, HIS SET UP IS 220. DON'T HAVE 220 IN MY SHOP. QUESTION CAN USE YOUR 110 WITH THIS SPINDLE??

  • I wired my vfd (2.2kw version) and tried test running the spindle. I configured to your specs on this website, only issue is we got an error code. Err 02, do you know what this is? OR have a list of error codes? Thank you

    Can you provide the model number of your VFD?

    Yes, I have the "YL600 - 2S - 2K20"

    It just came with a small booklet that is all in Chinese...

    Click the link to add information to this solution:
    I wired my vfd (2.2kw version) and tried test running the spindle. I configured to your specs on this website, only issue is we got an error code. Err 02, do you know what this is? OR have a list of error codes? Thank you

  • I AM INTERESTED IN THE 3 AXIS COMBO USB OPTION. NOTICE YOU ENDORSE PLANET-CNC FOR USE WITH THIS BUT WILL MACH3 INTERFACE WELL BEAK OUT BOARD?
  • Will your 2.5 KW spindle work with my Hitachi WJ200-022SF VFD and does it have a thermal couple temp output?

    From reading on the Hitachi WJ200-022SF VFD, it seems as it will work just fine with this VFD. However since we have not tried this cross match, I would carefully take each connection and setting into great consideration and detail on both the Hitachi recommendations for setup, as well as our spindles recommended setup.
    Our spindles do not have a thermal couple temperature output.

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    Will your 2.5 KW spindle work with my Hitachi WJ200-022SF VFD and does it have a thermal couple temp output?

  • I have a water cooled spindle I only need the VFD drive. Does the VFD come with instrutction on hooking the VFD to Mach3?

    The VFD does come with a manual that details the wiring and connection specifications, terminal features and a list of the parameters. There is no information on how to connect it to Mach3. It does detail the specifications within the parameters and terminal features on the analog input that is used with Mach3 and other control programs.

    Click the link to add information to this solution:
    I have a water cooled spindle I only need the VFD drive. Does the VFD come with instrutction on hooking the VFD to Mach3?

  • I’M LOOKING TO PURCHASE SPINDLE AND VFD WAS CURIOS IF THE SPINDLES COME WITH COLLETS SO WHICH ONES?

    Yes, all of the spindles come with collets. The collets have a 1/4" (6.35mm) bore for end mills that have a 1/4" shank. The ER specification is different for the 1.5kW (ER-11) and the 2.2kW (ER-20).

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    I’M LOOKING TO PURCHASE SPINDLE AND VFD WAS CURIOS IF THE SPINDLES COME WITH COLLETS SO WHICH ONES?

  • LIMIT SWITCHES FOR AXIS. THE PRINT SHOWS THAT YOU CAN WIRE LIMITS EITHER N.O. OR N.C. SO IF THIS IS CORRECT I WOULD NEED TO TELL BOARD IN SOFTWARE HOW LOOK AT THESE LIMITS, I'M GOING GET AN INPUT LOOSE DEPEND ON IT.

    BYCNC Response:
    This is correct. You will need to use a method appropriate for the software you are using. Also remember that NC switches are typically wired in series, while NO switches are normally wired in parallel.

    User Response:
    I am using the cnc planet software for your USB board. Are the limit configurations in this software?

    BYCNC Response:
    Yes, Planet CNC software is compatible with the use of limit switches. Configuration information will depend on your specific application. You can view Planet CNC's information here: http://www.planet-cnc.com/files/CNCUSBController.pdf

    Click the link to add information to this solution:
    LIMIT SWITCHES FOR AXIS. THE PRINT SHOWS THAT YOU CAN WIRE LIMITS EITHER N.O. OR N.C. SO IF THIS IS CORRECT I WOULD NEED TO TELL BOARD IN SOFTWARE HOW LOOK AT THESE LIMITS, I'M GOING GET AN INPUT LOOSE DEPEND ON IT.

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.