Question #: 13483

Question: 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD) Geven Me My contuy Bangladesh

Current Solution

Spindles are generally covered up to 1 year after date of purchase. We do not repair them in house, but we do work with our manufacturer to replace defective units. Generally if you have a defective unit covered under warranty, we will issue a replacement.

Respond:

Other Possible Solutions to this Question

  • what is the warranty period and do you repair these in house? 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)

    Spindles are generally covered up to 1 year after date of purchase. We do not repair them in house, but we do work with our manufacturer to replace defective units. Generally if you have a defective unit covered under warranty, we will issue a replacement.

    Click the link to add information to this solution:
    what is the warranty period and do you repair these in house? 2.2 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)

  • Is the "1.5 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)" spindle speed regulated? (Will maintain its speed under load)

    Absolutely. These spindles do not get bogged down under load like routers will. The speed is regulated and current will adjust with the load.

    Click the link to add information to this solution:
    Is the "1.5 kW (kilowatt) Water Cooled Spindle with Inverter (VFD)" spindle speed regulated? (Will maintain its speed under load)

  • Hi, I'm interested in the 1.5 kW (kilowatt) Water Cooled Spindle with Inverter (VFD), I would like to know about the run out of this spindle?

    Our spindles have a runout of less than .0001 in, which includes that collets that we sell. If you use a collet from another manufacturer, we cannot guarantee this TIR (Total Indicated Runout) dimension.

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    Hi, I'm interested in the 1.5 kW (kilowatt) Water Cooled Spindle with Inverter (VFD), I would like to know about the run out of this spindle?

  • Can the 2.2 KW water cooled spindle be fitted with a 1/2" chuck/collet ?

    Absolutely. You can have 1/2" collets used in 2.2kW spindles.

    Here is a link for the ER-20 1/2"ID Collet:
    https://www.buildyourcnc.com/item/spindle-collet-!5-er20-spindle-collet

    Click the link to add information to this solution:
    Can the 2.2 KW water cooled spindle be fitted with a 1/2" chuck/collet ?

  • I am interested in buying the water cooled 2.2 KW spindle for $339, how much does it weigh?

    The weight of the 2.2kW spindle without the VFD (variable frequency drive or inverter) is 11 lbs or 5 kg.

    The 2.2kW spindle with the VFD is 15 lbs or 6.8 kg.

    Additional Information:

    Click the link to add information to this solution:
    I am interested in buying the water cooled 2.2 KW spindle for $339, how much does it weigh?

  • [77] I have a 110 volt 2.2kw water cooled spindle. Can I run it with a 220 volt VFD?

    I have not tried connecting a 110V spindle to a 220V VFD; however, the parameters in a 220V VFD do allow changes to the values for the spindle motor. If you do plan on connecting the 110V spindle to a 220V VFD, damages can occur, so I would not recommend it.

    With that said, here is the output of an LLM:
    Using a 220-volt VFD (Variable Frequency Drive) to run a 110-volt spindle is technically possible, but it requires careful setup to avoid damaging the spindle. Here's what you need to consider:

    Check the VFD Specifications: Ensure that the VFD can be set up to output the correct voltage for your spindle. Many VFDs are capable of outputting variable voltages and can be configured via their programming settings to match the voltage requirements of the spindle.

    Adjust the Output Voltage: You'll need to configure the VFD to output 110 volts to match your spindle. This is crucial because supplying 220 volts to a 110-volt spindle would likely damage it permanently. Check the VFD's manual for instructions on how to adjust the output voltage settings.

    Set the Current Correctly: Besides voltage, make sure the output current does not exceed what your spindle can handle. The VFD should be configured to supply the current at the rating appropriate for the spindle’s power and voltage requirements.

    Consult the Manuals: Always refer to the manuals of both the spindle and the VFD. These documents can provide specific guidance on compatibility and settings.

    Consider Professional Installation: If you are not familiar with electrical systems or if the manuals do not provide clear guidance, it may be wise to hire a professional. This helps ensure that the setup is done safely and correctly.

    By taking these steps, you can safely use a 220-volt VFD with your 110-volt spindle, ensuring it operates efficiently without risk of damage. Just be meticulous with the settings and when in doubt, consult with or hire a professional.

    Click the link to add information to this solution:
    [77] I have a 110 volt 2.2kw water cooled spindle. Can I run it with a 220 volt VFD?

  • It is possible to control externally the 1.5kW Inverter (VFD) (220 Volt) with PWM so i can control the spindle rotation? Do you have the documentation? Thank you

    Our spindle VFD's, have a multitude of different connectors that can be used for different operations. There is a manual that comes with each VFD, and you can refer to page 11 for different functions and descriptions.

    We currently have a PWM, working with our machine, however it is connected via USB, and setup through Mach 3.
    Also if you may have misplaced or lost the manual here is a link to the pdf:

    (https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&uact=8&ved=0CCAQFjAAahUKEwibxaaIndTHAhXQlogKHZVyDFE&url=http%3A%2F%2Fwww.c-n-c.cz%2Fdownload%2Ffile.php%3Fid%3D42252&ei=_cHkVdvSC9CtogSV5bGIBQ&usg=AFQjCNHTQcxs-KhJkvkhMdxVFPzkoYJtsA&sig2=JAcZawTGMuC-t4wmn1z-rA)

    Click the link to add information to this solution:
    It is possible to control externally the 1.5kW Inverter (VFD) (220 Volt) with PWM so i can control the spindle rotation? Do you have the documentation? Thank you

  • Could I safely use a 2200w 220 to 110 converter and uninteruptable power supply with my 2.2kw inverter and spindle?

    Yes, you can use a 220 to 110 step down transformer to provide power to your 2.2kw VFD and spindle.

    Click the link to add information to this solution:
    Could I safely use a 2200w 220 to 110 converter and uninteruptable power supply with my 2.2kw inverter and spindle?

  • WHAT ARE THE OUTPUT INVERTER (VFD) CONNECTIONS TO SPINDLE?

    U - Pin1
    V - Pin2
    W - Pin3
    Pin4 Dead

    Additional Information:
    My home made cnc is a big problem with my NC connection. When in start my spindle it will be gone wrong. It will be limith switch problem anytime. Need help thanks.

    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    WHAT ARE THE OUTPUT INVERTER (VFD) CONNECTIONS TO SPINDLE?

  • hi, would like to make a change on my order, i purchase this part 2.2kW Spindle with 220V Inverter $528.00, and would like to make it for 110 volts instead of 220v. please

    Sure, not a problem at all. You will need to call our office and provide your information so that we can change the correct order.

    Our phone number can be seen by hovering over the "Need Help?" at the top right of each page.

    Click the link to add information to this solution:
    hi, would like to make a change on my order, i purchase this part 2.2kW Spindle with 220V Inverter $528.00, and would like to make it for 110 volts instead of 220v. please

  • 1.5KW water hose 1/4" ID - 3/8" OD does not fit in spindle fitting with ID 0.31"

    If you are using a silicone tube with a 1/4” ID, it will fit the nipple of the 1.5kW spindle water connections measuring an OD of 0.31”. The silicone will stretch and you will need to use water or saliva to help the tube fit.

    The tube ID being smaller than the nipple will help the seal prevent water from leaking.

    Click the link to add information to this solution:
    1.5KW water hose 1/4" ID - 3/8" OD does not fit in spindle fitting with ID 0.31"

  • Hi, I'm considering buying one of your 2.2 KW water cooled spindles. What is these spindles run out ?

    TIR specifications for the ER-20 collet used on 2.2KW Spindles is .0004 inches.

    Click the link to add information to this solution:
    Hi, I'm considering buying one of your 2.2 KW water cooled spindles. What is these spindles run out ?

  • Will your 2.5 KW spindle work with my Hitachi WJ200-022SF VFD and does it have a thermal couple temp output?

    From reading on the Hitachi WJ200-022SF VFD, it seems as it will work just fine with this VFD. However since we have not tried this cross match, I would carefully take each connection and setting into great consideration and detail on both the Hitachi recommendations for setup, as well as our spindles recommended setup.
    Our spindles do not have a thermal couple temperature output.

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    Will your 2.5 KW spindle work with my Hitachi WJ200-022SF VFD and does it have a thermal couple temp output?

  • WHAT ELECTRICAL CABLE DO I USE TO CONNECT VFD INVERTER SPINDLE?

    The type of wire that should be used between the spindle and the VFD (Variable Frequency Driver also called the inverter) should be of stranded type and we use between 18 and 16 AWG.

    The total current is divided among the three coil wires, therefor a wire gauge of 16 should be sufficient.

    Currently we use 20AWG 4 conductor.

    Additional Information:


    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    WHAT ELECTRICAL CABLE DO I USE TO CONNECT VFD INVERTER SPINDLE?

  • It seems that the water cooling lines inside my 2.2KW spindle are clogged. Is there a way to unclogg them?

    You can use a compressor to unclogg the water lines of the spindle. We use this method and it works every time (so far).

    Click the link to add information to this solution:
    It seems that the water cooling lines inside my 2.2KW spindle are clogged. Is there a way to unclogg them?

  • HOW DO YOU HOOK UP THE SPINDLE TO INVERTER?

    U - Pin1
    V - Pin2
    W - Pin3
    Pin4 Dead

    Additional Information:
    My home made cnc is a big problem with my NC connection. When in start my spindle it will be gone wrong. It will be limith switch problem anytime. Need help thanks.

    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    HOW DO YOU HOOK UP THE SPINDLE TO INVERTER?

  • HOW DO YOU SETUP THE SPINDLE INVERTER VFD?

    Change PD001 Source of Run Commands to '1'
    Change PD005 Max operating frequency to 400hz
    Change PD004 base frequency to 400hz
    Change PD003 Main frequency to 400hz
    Change PD006 Intermediate frequency to 2.5
    Change PD008 max voltage to 220v
    Change PD009 Intermediate voltage to 15v
    Change PD010 Min voltage to 8
    Change PD011 frequency lower limit to >100hz (120hz to start)
    Change PD142 7 Amps
    Change PD143 2
    Change PD144 3000

    Note: PD001 had to be changed back to 0 to allow for keypad control.
    Note2: I had to reverse U and V to get the spindle to go forward in FWD. (reverse any two wires, u&v or w&v for example)

    Additional Information:

    Click the link to add information to this solution:
    HOW DO YOU SETUP THE SPINDLE INVERTER VFD?

  • HOW DO YOU SETUP THE SPINDLE INVERTER?

    Change PD001 Source of Run Commands to '1'
    Change PD005 Max operating frequency to 400hz
    Change PD004 base frequency to 400hz
    Change PD003 Main frequency to 400hz
    Change PD006 Intermediate frequency to 2.5
    Change PD008 max voltage to 220v
    Change PD009 Intermediate voltage to 15v
    Change PD010 Min voltage to 8
    Change PD011 frequency lower limit to >100hz (120hz to start)
    Change PD142 7 Amps
    Change PD143 2
    Change PD144 3000

    Note: PD001 had to be changed back to 0 to allow for keypad control.
    Note2: I had to reverse U and V to get the spindle to go forward in FWD. (reverse any two wires, u&v or w&v for example)

    Additional Information:

    Click the link to add information to this solution:
    HOW DO YOU SETUP THE SPINDLE INVERTER?

  • HOW TO CONNECT THE SPINDLE INVERTER?

    U - Pin1
    V - Pin2
    W - Pin3
    Pin4 Dead

    Additional Information:
    My home made cnc is a big problem with my NC connection. When in start my spindle it will be gone wrong. It will be limith switch problem anytime. Need help thanks.

    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    HOW TO CONNECT THE SPINDLE INVERTER?

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.