[ Log In ]
[ Register ]

Question #: 13864

Question: 1.5KW water hose 1/4" ID - 3/8" OD does not fit in spindle fitting with ID 0.31"

Current Solution

If you are using a silicone tube with a 1/4” ID, it will fit the nipple of the 1.5kW spindle water connections measuring an OD of 0.31”. The silicone will stretch and you will need to use water or saliva to help the tube fit.

The tube ID being smaller than the nipple will help the seal prevent water from leaking.

Respond:

Other Possible Solutions to this Question

  • Hi. New to all this; can you recommend a water-cooled spindle set that will fit in a 3 1/2" fitting?

    Welcome to this wonderful world of fabrication. Our 2.2kW water cooled spindles measure 80 mm in diameter which is 3.14 inches. This is the standard for most spindles of this power. You may need to get a mount made for this diameter.

    2.2kW spindle and VFD:
    https://www.buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-vfd

    80mm Spindle mount:
    https://www.buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-80mm-mount

    Click the link to add information to this solution:
    Hi. New to all this; can you recommend a water-cooled spindle set that will fit in a 3 1/2" fitting?

  • I just purchased the 2.2 kW water cooled spindle. I also ordered a 1/8" collet to go with it, since I assume it comes with a 1/4" collet. Is this correct?

    Spindle comes with 1/4" collet.

    "All of our spindles come standard with a 1/4" collet. The 2.2kw, and 4.0kw, can be upgraded to a 1/2" collet with a separate purchase"

    Click the link to add information to this solution:
    I just purchased the 2.2 kW water cooled spindle. I also ordered a 1/8" collet to go with it, since I assume it comes with a 1/4" collet. Is this correct?

  • THE GANTRY MOUNTED SPINDLE WATER COOLER PUMP THAT I PURCHASED DOES NOT OPERATE NO MATTER HOW CONNECT THREE WIRES TO TWO WIRE POWER SUPPLY.

    The 12V power supply has 3 terminals for AC in: N, L and earth ground. The output of the 12V power supply has 2 DC + and - terminals. Cut the connectors off of the ends of the fan and pump wires. Strip the red and black wires of both units. The fan will connect to the 12V power supply red to the + and black to the -. The pump will connect in the same way, but the white is not connected.

    If you have a pump that has a grey and black wire on the large connector, the grey is the 12VDC V+ wire and the black wire goes to the V-. The extra wire does not need to be connected.

    Click the link to add information to this solution:
    THE GANTRY MOUNTED SPINDLE WATER COOLER PUMP THAT I PURCHASED DOES NOT OPERATE NO MATTER HOW CONNECT THREE WIRES TO TWO WIRE POWER SUPPLY.

  • Will your 2.5 KW spindle work with my Hitachi WJ200-022SF VFD and does it have a thermal couple temp output?

    From reading on the Hitachi WJ200-022SF VFD, it seems as it will work just fine with this VFD. However since we have not tried this cross match, I would carefully take each connection and setting into great consideration and detail on both the Hitachi recommendations for setup, as well as our spindles recommended setup.
    Our spindles do not have a thermal couple temperature output.

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    Will your 2.5 KW spindle work with my Hitachi WJ200-022SF VFD and does it have a thermal couple temp output?

  • BUILDING ONE OF YOUR GREENBULL 6X LONG AND 2.2 KILOWATT SPINDLE DOES NOT FIT. SEEMS LEAD SCREW YOU SENT WITH KIT IS SHORT 42" LOOKS LIKE IT NEEDS TO BE 5 OR 6 INCH LONGER. THIS CORRECT? WHAT THE NEEDED LENGTH FOR UNIT?
  • MY COMPUTER DOES NOT HAVE A PARALLEL PORT. HOW DO I INTERFACE WITH THE MACHINE?

    If your computer does not have a parallel port, all you will need is a low cost PCI parallel adapter card (these can be found on amazon for $15-$20). If you plan on using a laptop (not recommended) you can try to find a PCMCIA parallel adapter, but many people have frequent issues with this setup. A more expensive solution would be to purchase a USB smooth stepper board. Unfortunately, we do not supply any of these adapters and cannot attest to their reliability.

    Additional Information:
    ur gay

    Additional Information:

    Click the link to add information to this solution:
    MY COMPUTER DOES NOT HAVE A PARALLEL PORT. HOW DO I INTERFACE WITH THE MACHINE?

  • I bought a 1.5kw spindle that came with the ER11 6mm collet. I found collets for 1/4" and 1/2" but will these work with my existing nut? I see there is a nut for sale but it says its just for Bosh and Porter Cable etc.

    It is likely that if your Spindle's collet is ER11 specification than other size ER11 collets will work with your spindle.

    Click the link to add information to this solution:
    I bought a 1.5kw spindle that came with the ER11 6mm collet. I found collets for 1/4" and 1/2" but will these work with my existing nut? I see there is a nut for sale but it says its just for Bosh and Porter Cable etc.

  • MY COMPUTER DOES NOT HAVE A PARALLEL PORT. HOW DO I INTERFACE WITH THE BREAKOUT BOARD?

    If your computer does not have a parallel port, all you will need is a low cost PCI parallel adapter card (these can be found on amazon for $15-$20). If you plan on using a laptop (not recommended) you can try to find a PCMCIA parallel adapter, but many people have frequent issues with this setup. A more expensive solution would be to purchase a USB smooth stepper board. Unfortunately, we do not supply any of these adapters and cannot attest to their reliability.

    Additional Information:
    ur gay

    Additional Information:

    Click the link to add information to this solution:
    MY COMPUTER DOES NOT HAVE A PARALLEL PORT. HOW DO I INTERFACE WITH THE BREAKOUT BOARD?

  • what does it mean when my spindle VFD inverter shows OC-2?

    Remember, steps to correct and troubleshoot issues with any electrical devices should be done by a professional electrician.

    If you have an HY series VFD, the fault codes are below:

    OC-1: Over-current during ramp up or over-current at constant speed.
    Recommended actions: 1, 2, 3, 4

    OC-1: Over-current during ramp up or over-current at constant speed.
    Recommended actions: 1, 2, 5, 6

    OC-2: Over-current at deceleration or over-current at stop.
    Recommended actions: 1, 7, 2, 9, 10

    dL: Output short circuit.
    Recommended actions: 11, 1, 10

    Ou-1 or 2: Over-voltage at stop, over-voltage at acceleration, over-voltage at constant speed or over-voltage at deceleration
    Recommended actions: 12, 13

    Fb: Fuse break.
    Recommended actions: 14, 10

    Lu: Low voltage.
    Recommended actions: 15, 16, 17

    OH: Over heat of inverter.
    Recommended actions: 18, 19, 20

    OL-1: Inverter overload 150% per minute
    Recommended actions: 2, 21, 22

    OL-2: Motor overload 150% per minute.
    Recommended actions: 21, 23, 24, 25, 26, 21

    dT: Motor over-torque
    Recommended actions: 21, 23

    E.b.S.A or E.b.S.n or E.b.S.d or E.b.S.S: No feedback from the auxiliary coil or the lectromagnetic contactor
    Recommended action: 27

    bt: Braking transistor damage.
    Recommended action: 27

    CPu: CPU fault.
    Recommended action: 27

    E.E.E.S or E.E.E.n or E.E.E.d or E.E.E.A: EEPROM fault
    Recommended action: 27


    List of recommended actions:
    If error shows at ramp up or at constant speed:
    1. Check for a short circuit or partial short circuit and the insulation of the output wire is sufficient.
    2. Increase the capacity or the inverter if it is too small. Replace with an inverter that has a larger capacity
    3. Extend the ramp-up time
    4. Decrease the torque and increase the set value.
    5. Check if the motor is blocked and if there is a sudden change in load.
    6. Check if there is a sudden chance in the power supply voltage.
    7. Extend ramp down time
    9. DC breaking is too high. Decrease DC breaking
    10. Replace the inverter.
    11. Check to see if there is a short circuit with the connection wire of the motor.
    12. Extend the ramp-down time or add a breaking resistor.
    13. Check the mains supply voltage and insure there isn't ant sudden change in voltage.
    14. Send the inverter for repair.
    15. Check whether the input voltage is normal
    16. check whether there is a sudden change in load.
    17. Check whether there is any phase missing.
    18. Check the fan in the inverter. Is it spinning? Is it blocked? Does it have any foreign matter stuck on the fins of the fan? If so, clear the fan.
    19. Check the ambient temperature in the space that the inverter is placed.
    20. Check for adequate ventilation for the inverter where it is placed.
    21. Check for jamming or any sudden change with respect to mechanical load.
    22. Set the V/F curve correctly.
    23. The motor is too small.
    24. The motor is hot and the insulation of the motor degraded.
    25. Check if the voltage has a large variance.
    26. Check if there is a phase missing.
    27. Contact the supplier

    Additional Information:
    I have cnc wood carving machine 1325 the inverter showing error 0006

    Additional Information:
    What is uc3 error

    Additional Information:
    My inverter read error oc-1 high frequency how you can help me please


    Additional Information:
    My inverter read error oc-1 high frequency how you can help me please


    Additional Information:
    203

    Additional Information:
    E2 error

    Additional Information:
    Hello , I have an Redsail cnc and I get the following error " UC3 "after that the spindle stops arter a small knocking sound ,would there be an solution to this ?

    Additional Information:


    Additional Information:
    what does it mean when my spindle VFD shows E o and stops.


    Additional Information:
    Vfd er.01.5c

    Additional Information:
    CPFO error displayed reason

    Additional Information:
    Solve it

    Additional Information:
    My Spindle VFD Holip HLPA01D523C get error E.OC.A after factory reset. and now get error E.OC.n after i change the starting mode from Start from Starting
    Frequency to Frequency track start. whats wrong with the vactory setting?

    Additional Information:
    Er20

    Additional Information:
    Fault 503

    Additional Information:
    Fault 503

    Additional Information:
    What VFD do you have?

    Additional Information:
    When I on the motor the derave right oc2 it move then it stop again

    Additional Information:
    When I on the motor the derave right oc2 it move then it stop again


    Additional Information:
    what does it mean when my spindle VFD shows E.Lu.S and stops.

    Additional Information:
    Dear si my emetron ac drive ERR 05 PROBLEM

    Additional Information:
    Err04



    Additional Information:
    Err04


    Additional Information:
    Error 4

    Additional Information:
    Error 4

    Click the link to add information to this solution:
    what does it mean when my spindle VFD inverter shows OC-2?

  • I would like to purchase the 2.2 kW water cooled spindle, I would like to know the measured run-out of the spindle?

    Our spindles have a runout of less than .0001 in, which includes that collets that we sell. If you use a collet from another manufacturer, we cannot guarantee this TIR (Total Indicated Runout) dimension.

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    I would like to purchase the 2.2 kW water cooled spindle, I would like to know the measured run-out of the spindle?

  • I’M LOOKING TO PURCHASE SPINDLE AND VFD WAS CURIOS IF THE SPINDLES COME WITH COLLETS SO WHICH ONES?

    Yes, all of the spindles come with collets. The collets have a 1/4" (6.35mm) bore for end mills that have a 1/4" shank. The ER specification is different for the 1.5kW (ER-11) and the 2.2kW (ER-20).

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    I’M LOOKING TO PURCHASE SPINDLE AND VFD WAS CURIOS IF THE SPINDLES COME WITH COLLETS SO WHICH ONES?

  • WHAT SIZE WRENCHES DOES THIS SPINDLE TAKE TO TIGHTEN?

    To loosen and tighten the collet nut for the 2.2kW spindle, I use a 22mm wrench (spanner) for the shaft and a 30mm wrench for the nut.

    Click the link to add information to this solution:
    WHAT SIZE WRENCHES DOES THIS SPINDLE TAKE TO TIGHTEN?

  • I PURCHASED A VFD AND SPINDLE FROM FRIEND, HIS SET UP IS 220. DON'T HAVE 220 IN MY SHOP. QUESTION CAN USE YOUR 110 WITH THIS SPINDLE??

    Depending if the spindle can work with this specific VFD, it might be possible. However we would not like to risk you working unit, with a possible match so we would like more details on your specific model and any information available on the spindle itself.

    Response
    The only info on the spindle is 2.2KW 400HZ 220V. Made by Zhong Hua Jiang.

    Was originally on a Delta C200 vfd. That is 220 single phase.

    Click the link to add information to this solution:
    I PURCHASED A VFD AND SPINDLE FROM FRIEND, HIS SET UP IS 220. DON'T HAVE 220 IN MY SHOP. QUESTION CAN USE YOUR 110 WITH THIS SPINDLE??

  • Hello what is the thread size of the water cooling fittings on the 2.2kw spindle? I am wondering if I can replace the fittings with standard pc liquid cooling fittings, which are G1/4".

    They do have a similar looking thread as the G1/4”, but I will confirm in the morning. We use the G1/4” on the pump and radiator so it will be easy to determine this fit when I get into the office.

    Additional Information:
    Another FAQ says it is an M8, but I will confirm.

    Additional Information:
    These are M8x1 thread. I was able to find M8x1 3/8 barb fittings on Ebay. I plan to drill and tap my spindle to G1/4 though.

    Click the link to add information to this solution:
    Hello what is the thread size of the water cooling fittings on the 2.2kw spindle? I am wondering if I can replace the fittings with standard pc liquid cooling fittings, which are G1/4".

  • DOES THE SPINDLE RUN ON A 50HZ POWER SOURCE?

    The spindle inverter (VFD) will run on a 220V (or between 170V-250V) power source with either 50Hz or 60Hz.

    Click the link to add information to this solution:
    DOES THE SPINDLE RUN ON A 50HZ POWER SOURCE?

  • Do you recomend distilled water or coolant for your 80W laser tube with the CW-3000?

    We use purified water, but adding some coolant can be a benefit. The addition of coolant can keep the water in a state that maintains no growth of foreign organism like algae and the such. Additionally, If you are in a colder climate, antifreeze will work well.

    Additional Information:

    Click the link to add information to this solution:
    Do you recomend distilled water or coolant for your 80W laser tube with the CW-3000?

  • interest i nbuilding a 2X2' low budget 4-5 axes machine of 1-2 hp with tilting, rotating spindle up to 45 degrees off vertical

    If you go to our R&D section, you can vote for your machine and/or type a special request to create a machine that you might need.

    R&D:https://www.buildyourcnc.com/ResDev.aspx

    Click the link to add information to this solution:
    interest i nbuilding a 2X2' low budget 4-5 axes machine of 1-2 hp with tilting, rotating spindle up to 45 degrees off vertical

  • I HAVE THE REDFLY SYSTEM AND A 2.2KW SPINDLE - 110V HOW DO CONNECT SPINDAL?

    It is not necessary to connect the spindle VFD (Variable Frequency Drive also called an Inverter) to the computer or CNC motion electronics. The VFD can be controlled independently using the control panel on the VFD. The control panel has the ability to control all aspects of the spindle including Speed, Torque, limits, etc. However, you can connect the VFD to the computer so the CNC control program can control the spindle during the CNC Machine operation. You will need to connect the VFD to the computer via a serial conection (in this case, it is the RS-485 protocol).

    The following are instructions on how to connect the VFD to Mach3 via this RS-485 serial connection.

    The first thing you will need is the dynamic link library to pair with mach3 called the Huanyang VFD Mach3 PlugIn. You can find this file at the mach3 support forum here: http://www.machsupport.com/forum/index.php/topic,14182.0.html

    You will also need to download the Microsoft .net 3.5 framework and install it: https://www.microsoft.com/en-us/download/details.aspx?id=21

    Follow the pdf that comes with the library file, but here is a synopsis of what you need to do (I also added a lot more information that may be useful during this process as the manual does not cover the main connections that need to be done):

    You will need to program your VFD so that it knows how to communicate with mach3 and the computer (go into the programming mode of the VFD and change these parameters):
    - PD001 - value 2 - Enables with communication aspect of the VFD
    - PD002 - value 2 - Enables frequency control from the communcations port
    - PD163 - value 1 - VFD address
    - PD164 - value 1 - Baud rate of 9600 (speed of the communication)
    - PD165 - value 3 - 8N1 RTU - 8 bits (that's the size of the word that gets communicated), N (No parity or no error checking) and 1 (1 stop bit)

    Copy the dll file to the PlugIns folder of mach3.

    Connect the RX and TX lines to your computer. There are a couple ways you can do this, but the recommended way would be to use an FTDI USB device which converts a USB to a serial com port. The device will have Rx and Tx connectors to connect to the VFD terminals with the same labels. This method is recommended since serial ports are not as common in computers these days.

    Next, you will need to configure mach3 to use the plugin library. Start mach3 and click on Menu -> config ->Config Plugins. Enable the new plugin by clicking on the red cross on the left column next to the plug in. Restart mach3 after doing this.

    No you need to configure mach3 to use the HuanyangVFD plugin. Go to the ports & pins configuration and select the spindle setup tab. Make sure that the Disable Spindle Relays checkbox is unchecked. We don't want mach3 to output a signal for a relay since the spindle will start up and turn off within the VFD and not from an external relay.

    Next, go to the HuanyangVFD settings by clicking on Menu -> plugin control -> HuanyangVFD. Set the parameters to the same settings you put into the VFD programming. The com port will be shown as new hardward when you plug in the USB FTDI device. A little bubble will be displayed at the bottom right where it will notify you that a new device is being installed (be patient while windows assigns a com port). Alternatively, you can use the windows device manager to see which port was set for the new USB FTDI device). You may need to restart mach3 several times until you get the correct information displayed in the PD001 and PD002 fields. When the com port is correct and the other parameters, like baud and VFD address is the same as you entered in the programming, then the PD001 and PD002 will show the number 2, otherwise, a 99 will appear which means that communication was not successful.

    You can now control the on/off and RPM of the spindle using the RS485 communication between mach3 and the VFD.

    Additional Information:
    The question was how to connect the spindle to the redfy. I did not receive a VFD.
    I have the redFly system and a 2.2kW Spindle - 110V how do i connect the spindle?

    Additional Information:
    If you received a spindle without a VFD, please contact us asap. Our spindle will not work without a VFD.

    Additional Information:
    Hi, how is this setup in mach4?

    Click the link to add information to this solution:
    I HAVE THE REDFLY SYSTEM AND A 2.2KW SPINDLE - 110V HOW DO CONNECT SPINDAL?

  • THE SEND MAIL IN CONTACT US PAGE OF BUILDYOURCNC.COM WEBSITE DOES NOT WORK. ALSO CALLED MAILTO:

    You will need to change the default attribute of the browser that you are using (i.e. Google Chrome, IE, Firefox).

    Instructions to change this default attribute:
    1. Click on the "start menu"
    2. Click on "control panel"
    3. Click on "programs"
    4. Click on "default programs"
    5. Click on "set you default programs"
    6. Select the browser that you would like to fix
    7. Click on "choose defaults for this program"
    8. Find where it says "mailto" and set that to the default that you desire.

    Click the link to add information to this solution:
    THE SEND MAIL IN CONTACT US PAGE OF BUILDYOURCNC.COM WEBSITE DOES NOT WORK. ALSO CALLED MAILTO:

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.